• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:45:13 on August 5, 2001

    Entry number 69491

    keyword=Start_Run_2624,Run_type=other,beam_energy=1.197,beam_halfwaveplate=out,beam_polarization=82,beam_raster=on,comment_text=check coda after adaql2 reboot,daq_mode=both HRS daq,leftarm_p=1123,leftarm_theta=18.6,rightarm_p=1123,rightarm_theta=18.6,target_halfwaveplate=out,target_name=shapiro,target_polarization=48,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 2624 at Sun Aug 5 19:45:01 EDT 2001
    ; LEFT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T4 to measure efficiency
    ;
    ps3=8,ps4=8,ps8=65535
    Right Arm Q1 power supply current : 1203.12
    Right Arm Q1 momentum : 1.60004
    Right Arm Q1 gauss meter : -0.02996
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 688.508
    Right Arm Q2 momentum : 1.59982
    Right Arm Q2 gauss meter : 0.362
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 550.793
    Right Arm D1 momentum : 1.6
    Right Arm D1 NMR : 0.593741
    Right Arm Q3 power supply current : 636.563
    Right Arm Q3 momentum : 1.59987
    Right Arm Q3 gauss meter : 0.2856
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1203.55
    Left Arm Q1 momentum : 1.59975
    Left Arm Q1 gauss meter : -0.10176
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 688.882
    Left Arm Q2 momentum : 1.59982
    Left Arm Q2 gauss meter : 0.3636
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 537.517
    Left Arm D1 momentum : 1.60001
    Left Arm D1 NMR : 0.592148
    Left Arm Q3 power supply current : 637.113
    Left Arm Q3 momentum : 1.60031
    Left Arm Q3 gauss meter : -0.3185
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0197151
    Current on Unser monitor : 6.18199
    Current on Upstream bcm : 0.019215
    Current on Downstream bcm : 0.0202152
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    Beam energy : 1197.93
    MBSY1c magnet current (amp) : 49.6474
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.86875
    HacR_HPE1313A:0_Ch58 : -0.524414
    HacR_HPE1313A:0_Ch55 : 22.9492
    HacR_HPE1313A:0_Ch54 : -0.821289
    HacR_alignROLL : -0.28973
    HacR_alignPITCH : 0.0633948
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.154297
    HacL_HPE1313A:0_Ch55 : 24.707
    HacL_HPE1313A:0_Ch54 : -0.0991211
    HacL_alignROLL : 0.0956539
    HacL_alignPITCH : 0.135971
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.6002
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6033
    Wien angle : 2.38446
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 18.827
    Wien field : 0.68176
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1