• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 03:36:35 on August 10, 2001

    Entry number 70235

    keyword=Start_Run_21746,Run_type=production,beam_energy=3.469,beam_halfwaveplate=out,beam_polarization=70.0,beam_raster=on,comment_text=junk,daq_mode=both HRS daq,leftarm_p=1600,leftarm_theta=18.6,rightarm_p=1600,rightarm_theta=18.6,target_halfwaveplate=out,target_name=Shapiro,target_polarization=38.3,target_type=Polarized He-3 270deg
    Beginning-of-run EPICS data for Run Number 21746 at Fri Aug 10 03:34:40 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 1203.16
    Right Arm Q1 momentum : 1.60009
    Right Arm Q1 gauss meter : -0.02996
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 688.623
    Right Arm Q2 momentum : 1.60008
    Right Arm Q2 gauss meter : 0.362
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 550.801
    Right Arm D1 momentum : 1.6
    Right Arm D1 NMR : 0.593741
    Right Arm Q3 power supply current : 636.495
    Right Arm Q3 momentum : 1.5996
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1203.47
    Left Arm Q1 momentum : 1.59966
    Left Arm Q1 gauss meter : -0.10175
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 688.943
    Left Arm Q2 momentum : 1.59996
    Left Arm Q2 gauss meter : 0.3637
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 537.508
    Left Arm D1 momentum : 1.6
    Left Arm D1 NMR : 0.592145
    Left Arm Q3 power supply current : 637.045
    Left Arm Q3 momentum : 1.60014
    Left Arm Q3 gauss meter : -0.3184
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 11.6457
    Current on Unser monitor : 18.0668
    Current on Upstream bcm : 11.5663
    Current on Downstream bcm : 11.7251
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 3469.34
    MBSY1c magnet current (amp) : 144.495
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.523926
    HacR_HPE1313A:0_Ch55 : 23.1445
    HacR_HPE1313A:0_Ch54 : -0.814941
    HacR_alignROLL : -0.283088
    HacR_alignPITCH : 0.0645598
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.150879
    HacL_HPE1313A:0_Ch55 : 24.8047
    HacL_HPE1313A:0_Ch54 : -0.101562
    HacL_alignROLL : 0.0933741
    HacL_alignPITCH : 0.138525
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.6003
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6033
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9 !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1