• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name A.Vacheret

    Log entry time 13:14:07 on August10,2001

    Entry number 70346

    keyword=charge asymmetry slope calibration

    We made a calibration for one charge asymmetry slope (insertable HWP out).
    list of runs and RHWP position :

    run...........HWP pos...........Aq +- errAq

    run 1887.........400....................562+-26
    run 1889.........410....................340+-24
    run 1890.........420....................179+-26
    run 1891.........430..................... 1+_ 35
    run 1892.........440..................-339+-37 (this point doesn't make sense)
    run 1893.........450..................-279+-24

    The slope is -17 ppm/step now instead of -7.6 which was used before. It's seems to
    be consistant with the overcorrection seen in last couple of runs...

    run 1892 is not considered in the calibration we had almost no beam during this run.




    FIGURE 1