• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:46:51 on August 11, 2001

    Entry number 70565

    keyword=Start_Run_21812,Run_type=production,beam_energy=3.469,beam_halfwaveplate=out,beam_polarization=70.0,beam_raster=on,comment_text=PRODUCTION,daq_mode=both HRS daq,leftarm_p=1600,leftarm_theta=18.6,rightarm_p=1600,rightarm_theta=18.6,target_halfwaveplate=in,target_name=Shapiro,target_polarization=37.24,target_type=Polarized He-3 90deg
    Beginning-of-run EPICS data for Run Number 21812 at Sat Aug 11 21:46:34 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 1203.23
    Right Arm Q1 momentum : 1.60018
    Right Arm Q1 gauss meter : -0.02997
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 688.672
    Right Arm Q2 momentum : 1.6002
    Right Arm Q2 gauss meter : 0.362
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 550.794
    Right Arm D1 momentum : 1.6
    Right Arm D1 NMR : 0.59374
    Right Arm Q3 power supply current : 636.569
    Right Arm Q3 momentum : 1.60005
    Right Arm Q3 gauss meter : 0.2856
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1203.47
    Left Arm Q1 momentum : 1.59966
    Left Arm Q1 gauss meter : -0.10173
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 689.065
    Left Arm Q2 momentum : 1.60024
    Left Arm Q2 gauss meter : 0.3637
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 537.509
    Left Arm D1 momentum : 1.6
    Left Arm D1 NMR : 0.592146
    Left Arm Q3 power supply current : 636.949
    Left Arm Q3 momentum : 1.5999
    Left Arm Q3 gauss meter : -0.3184
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 12.1331
    Current on Unser monitor : 17.5747
    Current on Upstream bcm : 12.0494
    Current on Downstream bcm : 12.2168
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 3469.34
    MBSY1c magnet current (amp) : 144.495
    Radiator 5V Linear Supply : 0.00732601
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865137
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.521973
    HacR_HPE1313A:0_Ch55 : 23.1934
    HacR_HPE1313A:0_Ch54 : -0.812988
    HacR_alignROLL : -0.281492
    HacR_alignPITCH : 0.0660403
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.151367
    HacL_HPE1313A:0_Ch55 : 24.9512
    HacL_HPE1313A:0_Ch54 : -0.102539
    HacL_alignROLL : 0.0926389
    HacL_alignPITCH : 0.138236
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.6003
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6034
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1