Main INDEX
Monthly INDEX
PREV
NEXT
User name Ransome
Log entry time 16:05:54 on August19,2001
Entry number 71349
keyword=shift summary - day shift
8:00 Begin shift with NMR measurement N- 42.0 E - 41.8
8:24 Done with NMR, request beam
8:26 beam back
8:35 beam off, MCC says magnet in Hall C line needs to be cycled (est. 5 minutes)
8:44 beam back
10:23 beam off, MCC says magnet needs to be cycled again (est. a few minutes)
10:28 beam back
11:15 beam off, magnet cycling again
11:20 beam back
12:00 and all's well. Smooth running except for frequent FSD trips, which
are costing us 20-25% of the time
13:00 stop beam, prepare NMR measurement
13:35 done with NMR N - 41.6% E - 41.8%
13:39 beam back
14:35 We found 100% dead time on right arm, about 10 minutes into run
21933. ROC 15 dead. Restarted it, but still had 100% dead. Finally
killed runcontrol and restarted a couple times, got everything going at 15:15
Next good runs 2936, 21936, 2050 (parity)
We did not get the startup or end script for run 21936,
16:00 end of shift
Run Summary
Run Events Run Events End time
=============================
2925 182 K 21925 169 K 7:57
2926 142 K 21926 131 K 9:10
2927 213 K 21927 196 K 9:57
2928 164 K 21928 152 K 10:43
2929 150 K 21929 138 K 11:29
2930 204 K 21930 189 K 12:15
2931 193 K 21931 180 K 13:00
2932 182 K 21932 170 K 14:24