• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:33:46 on August 22, 2001

    Entry number 71853

    keyword=End_of_Run_31036
    ****************************
     Run Number: 31036
     End of Run Comment:
    Run_type=production,beam_energy=4.60,beam_halfwaveplate=out,beam_polarization=78.0,beam_raster=on,comment_text=Production Data,daq_mode=both HRS daq,leftarm_p=1990,leftarm_theta=18.6,rightarm_p=1990,rightarm_theta=18.6,target_halfwaveplate=out,target_name=Shapiro,target_polarization=42,target_type=Polarized He-3 270deg
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps8=65535   
    
    EVENTS[0]: 1767304      [+]: 867071       [-]: 866727       
    TIME  [0]: 42.737 mins  [+]: 20.971 mins  [-]: 20.973 mins  
    LIVE  [0]:  91.49%      [+]:  91.46%      [-]:  91.52%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:734.2/734.2 Hz   T2[0] [PRES/REAL]:19.1/19.1 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:734.4/734.4 Hz   T2[+] [PRES/REAL]:19.0/19.0 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:733.4/733.4 Hz   T2[-] [PRES/REAL]:19.2/19.2 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:1882600/1882600  T2[0] [PRES/REAL]:  49036/49036    T8[0] [PRES/REAL]:     40/2625789  
    T1[+] [PRES/REAL]: 924114/924114   T2[+] [PRES/REAL]:  23909/23909    T8[+] [PRES/REAL]:     19/1288478  
    T1[-] [PRES/REAL]: 922855/922855   T2[-] [PRES/REAL]:  24197/24197    T8[-] [PRES/REAL]:     19/1288574  
    
    AVERAGE CURRENT
    BCM x1 : 9.5819 uA  BCM x3 : 9.6270 uA  BCM x10: 9.6567 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    24.77 ppm     BCM u3 :    9.828 ppm     BCM u10:    5.077 ppm     
    BCM d1 :    30.84 ppm     BCM d3 :    4.291 ppm     BCM d10:    3.888 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02438        BCM u3 [0]:0.02444        BCM u10[0]:0.02455        
    BCM u1 [+]:0.01196        BCM u3 [+]:0.01199        BCM u10[+]:0.01204        
    BCM u1 [-]:0.01196        BCM u3 [-]:0.01199        BCM u10[-]:0.01204        
    
    BCM d1 [0]:0.02476        BCM d3 [0]:0.02493        BCM d10[0]:0.02497        
    BCM d1 [+]:0.01215        BCM d3 [+]:0.01223        BCM d10[+]:0.01225        
    BCM d1 [-]:0.01215        BCM d3 [-]:0.01223        BCM d10[-]:0.01225        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 31036 at Wed Aug 22 12:33:34 EDT 2001
    Right Arm D1 momentum : 1.99
    Right Arm arm angle : 18.5999
    Left Arm D1 momentum : 1.99
    Left Arm arm angle : 18.6033
    Tiefenbach Hall A energy :
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 1496.43
    Right Arm Q1 momentum : 1.9901
    Right Arm Q1 gauss meter : -0.03725
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 856.364
    Right Arm Q2 momentum : 1.98985
    Right Arm Q2 gauss meter : 0.4501
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 691.487
    Right Arm D1 momentum : 1.99
    Right Arm D1 NMR : 0.738465
    Right Arm Q3 power supply current : 791.905
    Right Arm Q3 momentum : 1.99017
    Right Arm Q3 gauss meter : 0.3552
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1497.12
    Left Arm Q1 momentum : 1.98998
    Left Arm Q1 gauss meter : -0.12662
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 856.962
    Left Arm Q2 momentum : 1.99016
    Left Arm Q2 gauss meter : 0.452
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 675.164
    Left Arm D1 momentum : 1.99
    Left Arm D1 NMR : 0.73637
    Left Arm Q3 power supply current : 792.189
    Left Arm Q3 momentum : 1.98983
    Left Arm Q3 gauss meter : -0.3962
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 9.84492
    Current on Unser monitor : 16.5524
    Current on Upstream bcm : 9.6989
    Current on Downstream bcm : 9.99094
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy : 4606.51
    MBSY1c magnet current (amp) : 192.153
    MBSY1c Bdl : 1.14956e+06
    MBSY3c Hall C Beam energy : 2336.25
    Tiefenbach Hall A energy : 4597.01
    Tiefenbach Hall C energy : 2331.83
    Delta(E)/E width (MV_AI_DXWID) : 0.502781
    IPM1C12.XPOS : 0.00803268
    IPM1H04A.XPOS : 0.100242
    IPM1H04A.YPOS : -1.47998
    IPM1H04B.XPOS : 0.060893
    IPM1H04B.YPOS : -1.61914
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.528809
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.831543
    HacR_alignROLL : -0.302774
    HacR_alignPITCH : 0.0584034
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.147949
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.097168
    HacL_alignROLL : 0.0951853
    HacL_alignPITCH : 0.138991
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868701
    Wien angle : -22.9767
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -584.99
    Wien field : 16.362
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Beam Half-wave plate (off=out) : OFF
    OTR x-position : 2.36784
    OTR y-position : -1.43147
    OTR x-width : 0.935118
    OTR y-width : 0.850951
    OTR data valid flag : Yes
    Polarized 3He Target RTD #1 : 0
    Polarized 3He Target RTD #2 : 44.4141
    Polarized 3He Target RTD #3 : 47.9395
    Polarized 3He Target RTD #4 : 81.5234
    Polarized 3He Target RTD #5 : 47.6172
    Polarized 3He Target RTD #6 : 180
    Polarized 3He Target RTD #7 : 180.645
    Polarized 3He Ref. Cell RTD #8 : 47.6367
    Polarized 3He Ref. Cell RTD #9 : -49.7461
    Polarized 3He Ref. Cell RTD #10 : -42.2656
    Polarized 3He Target Ref. Cell Gas Pres. : 42.065
    Polarized 3He Target Ref. Cell Sys.Vac. : 1109.41
    Polarized 3He Target Cooling Jet : 30.0586
    Polarized 3He Target OVEN RTD : 169.9
    Polarized 3He Target OVEN SP1 SET : 0
    Polarized 3He Target OVEN SP1 : 170
    Polarized 3He Target OVEN AL1 SET : 0
    Polarized 3He Target OVEN AL1 : 150
    Polarized 3He Target OVEN AL1 STATUS : enabled
    Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
    Polarized 3He Target Half-Wave Plate STAT: 1200000
    Polarized 3He Target Position (PA) : 136.931
    Polarized 3He Target Position (POS) : Pol. He Cell
    Polarized 3He Target Position (DA) : 136.931
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 2
    Polarized 3He Laser#1 Current : 38
    Polarized 3He Laser#1 Temperature : 14
    Polarized 3He Laser#2 State : 2
    Polarized 3He Laser#2 Current : 37
    Polarized 3He Laser#2 Temperature : 22.4
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 40
    Polarized 3He Laser#3 Temperature : 27.9
    Polarized 3He Laser#4 State : 2
    Polarized 3He Laser#4 Current : 40
    Polarized 3He Laser#4 Temperature : 15.4
    Polarized 3He Laser#5 State : 0
    Polarized 3He Laser#5 Current : 36.5
    Polarized 3He Laser#5 Temperature : 18.1
    Polarized 3He Laser#6 State : 0
    Polarized 3He Laser#6 Current : 40
    Polarized 3He Laser#6 Temperature : 11.3
    Polarized 3He Laser#7 State : 0
    Polarized 3He Laser#7 Current : 36.5
    Polarized 3He Laser#7 Temperature : 19.1
    Polarized 3He Coil Current Longitudinal : 0.068
    Polarized 3He Coil Current Transverse : -7.3759
     
    Parity run number: 3136