• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 20:53:03 on August 22, 2001

    Entry number 71887

    keyword=Start_Run_3042,Run_type=production,beam_energy=4.60,beam_halfwaveplate=out,beam_polarization=78.0,beam_raster=on,comment_text=Production Data,daq_mode=both HRS daq,leftarm_p=1990,leftarm_theta=18.6,rightarm_p=1990,rightarm_theta=18.6,target_halfwaveplate=out,target_name=Shapiro,target_polarization=44,target_type=Polarized He-3 270deg
    Beginning-of-run EPICS data for Run Number 3042 at Wed Aug 22 20:52:54 EDT 2001
    ; LEFT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T4 to measure efficiency
    ;
    ps3=1,ps4=1,ps8=65535
    Right Arm Q1 power supply current : 1496.25
    Right Arm Q1 momentum : 1.98987
    Right Arm Q1 gauss meter : -0.03726
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 856.395
    Right Arm Q2 momentum : 1.98992
    Right Arm Q2 gauss meter : 0.4501
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 691.478
    Right Arm D1 momentum : 1.99
    Right Arm D1 NMR : 0.738465
    Right Arm Q3 power supply current : 791.815
    Right Arm Q3 momentum : 1.98994
    Right Arm Q3 gauss meter : 0.3552
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1497.12
    Left Arm Q1 momentum : 1.98998
    Left Arm Q1 gauss meter : -0.1266
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 856.794
    Left Arm Q2 momentum : 1.98977
    Left Arm Q2 gauss meter : 0.452
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 675.164
    Left Arm D1 momentum : 1.99
    Left Arm D1 NMR : 0.73637
    Left Arm Q3 power supply current : 792.358
    Left Arm Q3 momentum : 1.99026
    Left Arm Q3 gauss meter : -0.3962
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 9.25746
    Current on Unser monitor : 15.3136
    Current on Upstream bcm : 9.12519
    Current on Downstream bcm : 9.38973
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 9.25128
    Beam energy : 4606.51
    MBSY1c magnet current (amp) : 192.153
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865137
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.52832
    HacR_HPE1313A:0_Ch55 : 21.9727
    HacR_HPE1313A:0_Ch54 : -0.832031
    HacR_alignROLL : -0.302716
    HacR_alignPITCH : 0.0584701
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.146973
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.0966797
    HacL_alignROLL : 0.095627
    HacL_alignPITCH : 0.139864
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.5999
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6033
    Wien angle : -22.9767
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -584.99
    Wien field : 16.362
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1