• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 01:53:06 on August 23, 2001

    Entry number 71922

    keyword=Start_Run_3048,Run_type=production,beam_energy=4.60,beam_halfwaveplate=out,beam_polarization=78.0,beam_raster=on,comment_text=Production Data,daq_mode=both HRS daq,leftarm_p=1990,leftarm_theta=18.6,rightarm_p=1990,rightarm_theta=18.6,target_halfwaveplate=out,target_name=Shapiro,target_polarization=44,target_type=Polarized He-3 270deg
    Beginning-of-run EPICS data for Run Number 3048 at Thu Aug 23 01:52:57 EDT 2001
    ; LEFT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T4 to measure efficiency
    ;
    ps3=1,ps4=1,ps8=65535
    Right Arm Q1 power supply current : 1496.35
    Right Arm Q1 momentum : 1.99001
    Right Arm Q1 gauss meter : -0.03725
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 856.526
    Right Arm Q2 momentum : 1.99022
    Right Arm Q2 gauss meter : 0.4502
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 691.486
    Right Arm D1 momentum : 1.99
    Right Arm D1 NMR : 0.738466
    Right Arm Q3 power supply current : 791.82
    Right Arm Q3 momentum : 1.98995
    Right Arm Q3 gauss meter : 0.3552
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1497.16
    Left Arm Q1 momentum : 1.99003
    Left Arm Q1 gauss meter : -0.12661
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 856.851
    Left Arm Q2 momentum : 1.9899
    Left Arm Q2 gauss meter : 0.452
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 675.177
    Left Arm D1 momentum : 1.99
    Left Arm D1 NMR : 0.736372
    Left Arm Q3 power supply current : 792.188
    Left Arm Q3 momentum : 1.98983
    Left Arm Q3 gauss meter : -0.3962
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 9.9374
    Current on Unser monitor : 16.2244
    Current on Upstream bcm : 9.8391
    Current on Downstream bcm : 10.0711
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 9.67057
    Beam energy : 4606.51
    MBSY1c magnet current (amp) : 192.153
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.530762
    HacR_HPE1313A:0_Ch55 : 21.6797
    HacR_HPE1313A:0_Ch54 : -0.833008
    HacR_alignROLL : -0.303005
    HacR_alignPITCH : 0.0567908
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.148926
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0966797
    HacL_alignROLL : 0.0942964
    HacL_alignPITCH : 0.13811
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.5999
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6033
    Wien angle : -22.9767
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -584.99
    Wien field : 16.362
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1