    User name adev

    Log entry time 21:45:23 on September 5, 2001

    Entry number 73524

    keyword=End_of_Run_3305
    ****************************
     Run Number: 3305
     End of Run Comment:
    Run_type=production,beam_energy=5.727,beam_halfwaveplate=out,beam_polarization=82.0,beam_raster=on,comment_text=raster check,daq_mode=both HRS daq,leftarm_p=2270,leftarm_theta=18.6,rightarm_p=2270,rightarm_theta=18.6,target_halfwaveplate=out,target_name=virginia one,target_polarization=43.3,target_type=Polarized He-3   0deg
     
    
    PRESCALE FACTORS:ps3=1   ps4=1   ps8=65535   
    
    EVENTS[0]: 2016128      [+]: 995894       [-]: 983995       
    TIME  [0]: 55.405 mins  [+]: 27.194 mins  [-]: 27.194 mins  
    LIVE  [0]:  89.01%      [+]:  88.99%      [-]:  89.03%      
    
    TRIGGER RATES:
    T3[0] [PRES/REAL]:653.9/653.9 Hz   T4[0] [PRES/REAL]:27.4/27.4 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T3[+] [PRES/REAL]:658.6/658.6 Hz   T4[+] [PRES/REAL]:27.3/27.3 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T3[-] [PRES/REAL]:649.8/649.8 Hz   T4[-] [PRES/REAL]:27.5/27.5 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T3[0] [PRES/REAL]:2173885/2173885  T4[0] [PRES/REAL]:  91107/91107    T8[0] [PRES/REAL]:     51/3404061  
    T3[+] [PRES/REAL]:1074558/1074558  T4[+] [PRES/REAL]:  44561/44561    T8[+] [PRES/REAL]:     25/1670781  
    T3[-] [PRES/REAL]:1060267/1060267  T4[-] [PRES/REAL]:  44905/44905    T8[-] [PRES/REAL]:     25/1670774  
    
    AVERAGE CURRENT
    BCM x1 : 9.6228 uA  BCM x3 : 9.6694 uA  BCM x10: 9.6998 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -15.14 ppm     BCM u3 :   -31.03 ppm     BCM u10:   -35.89 ppm     
    BCM d1 :   -13.81 ppm     BCM d3 :   -30.23 ppm     BCM d10:   -36.04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03174        BCM u3 [0]:0.03183        BCM u10[0]:0.03198        
    BCM u1 [+]:0.01558        BCM u3 [+]:0.01562        BCM u10[+]:0.0157         
    BCM u1 [-]:0.01558        BCM u3 [-]:0.01562        BCM u10[-]:0.0157         
    
    BCM d1 [0]:0.03223        BCM d3 [0]:0.03246        BCM d10[0]:0.03251        
    BCM d1 [+]:0.01582        BCM d3 [+]:0.01593        BCM d10[+]:0.01596        
    BCM d1 [-]:0.01582        BCM d3 [-]:0.01593        BCM d10[-]:0.01596        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3305 at Wed Sep 5 21:45:09 EDT 2001
    Right Arm D1 momentum : 2.27
    Right Arm arm angle : 18.6029
    Left Arm D1 momentum : 2.27
    Left Arm arm angle : 18.6015
    Tiefenbach Hall A energy : 5726.95
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 1706.88
    Right Arm Q1 momentum : 2.26998
    Right Arm Q1 gauss meter : -0.04248
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 976.971
    Right Arm Q2 momentum : 2.27009
    Right Arm Q2 gauss meter : 0.5134
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 795.024
    Right Arm D1 momentum : 2.27
    Right Arm D1 NMR : 0.84237
    Right Arm Q3 power supply current : 903.306
    Right Arm Q3 momentum : 2.27013
    Right Arm Q3 gauss meter : 0.4051
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1707.79
    Left Arm Q1 momentum : 2.27
    Left Arm Q1 gauss meter : -0.14443
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 977.249
    Left Arm Q2 momentum : 2.26951
    Left Arm Q2 gauss meter : 0.5154
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 776.572
    Left Arm D1 momentum : 2.27
    Left Arm D1 NMR : 0.839964
    Left Arm Q3 power supply current : 903.721
    Left Arm Q3 momentum : 2.26998
    Left Arm Q3 gauss meter : -0.452
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 11.9218
    Current on Unser monitor : 17.3868
    Current on Upstream bcm : 11.7836
    Current on Downstream bcm : 12.06
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 11.8237
    MBSY1c Hall A Beam energy : 5738.82
    MBSY1c magnet current (amp) : 239.898
    MBSY1c Bdl : 1.43213e+06
    MBSY3c Hall C Beam energy : 2335.85
    Tiefenbach Hall A energy : 5726.95
    Tiefenbach Hall C energy : 2330.44
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00173318
    IPM1H04A.XPOS : 0.180477
    IPM1H04A.YPOS : -1.53724
    IPM1H04B.XPOS : -0.040489
    IPM1H04B.YPOS : -1.53892
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.525879
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.825195
    HacR_alignROLL : -0.295121
    HacR_alignPITCH : 0.0608288
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.141602
    HacL_HPE1313A:0_Ch55 : 23.4863
    HacL_HPE1313A:0_Ch54 : -0.128906
    HacL_alignROLL : 0.0669202
    HacL_alignPITCH : 0.145111
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868701
    Wien angle : 6.23933
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 112.69
    Wien field : 3.2724
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Beam Half-wave plate (off=out) : OFF
    OTR x-position : 2.26649
    OTR y-position : -1.31218
    OTR x-width : 1.18599
    OTR y-width : 1.07876
    OTR data valid flag : Yes
    Polarized 3He Target RTD #1 : 53.0371
    Polarized 3He Target RTD #2 : 51.7578
    Polarized 3He Target RTD #3 : 59.8926
    Polarized 3He Target RTD #4 : 51.4258
    Polarized 3He Target RTD #5 : 50.5566
    Polarized 3He Target RTD #6 : 181.055
    Polarized 3He Target RTD #7 : 173.965
    Polarized 3He Ref. Cell RTD #8 : 47.793
    Polarized 3He Ref. Cell RTD #9 : -49.8438
    Polarized 3He Ref. Cell RTD #10 : -46.2891
    Polarized 3He Target Ref. Cell Gas Pres. : 54.7592
    Polarized 3He Target Ref. Cell Sys.Vac. : 1107.41
    Polarized 3He Target Cooling Jet : 14.7803
    Polarized 3He Target OVEN RTD : 170.1
    Polarized 3He Target OVEN SP1 SET : 170
    Polarized 3He Target OVEN SP1 : 170
    Polarized 3He Target OVEN AL1 SET : 0
    Polarized 3He Target OVEN AL1 : 150
    Polarized 3He Target OVEN AL1 STATUS : enabled
    Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
    Polarized 3He Target Half-Wave Plate STAT: 1200000
    Polarized 3He Target Position (PA) : 136.931
    Polarized 3He Target Position (POS) : Pol. He Cell
    Polarized 3He Target Position (DA) : 136.931
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 0
    Polarized 3He Laser#1 Current : 38
    Polarized 3He Laser#1 Temperature : 14
    Polarized 3He Laser#2 State : 0
    Polarized 3He Laser#2 Current : 37.2
    Polarized 3He Laser#2 Temperature : 22
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 40
    Polarized 3He Laser#3 Temperature : 27.9
    Polarized 3He Laser#4 State : 0
    Polarized 3He Laser#4 Current : 40
    Polarized 3He Laser#4 Temperature : 15.1
    Polarized 3He Laser#5 State : 2
    Polarized 3He Laser#5 Current : 36.5
    Polarized 3He Laser#5 Temperature : 18.1
    Polarized 3He Laser#6 State : 2
    Polarized 3He Laser#6 Current : 40
    Polarized 3He Laser#6 Temperature : 11.3
    Polarized 3He Laser#7 State : 2
    Polarized 3He Laser#7 Current : 36.5
    Polarized 3He Laser#7 Temperature : 19.1
    Polarized 3He Coil Current Longitudinal : -7.0276
    Polarized 3He Coil Current Transverse : -0.1189
     
    Parity run number: 3403