• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:13:51 on September 12, 2001

    Entry number 74246

    keyword=End_of_Run_31425
    ****************************
     Run Number: 31425
     End of Run Comment:
    Run_type=cosmics,beam_energy=5.727,beam_halfwaveplate=in,beam_polarization=83.0,beam_raster=on,comment_text=test,daq_mode=both HRS daq,leftarm_p=2270,leftarm_theta=18.6,rightarm_p=2270,rightarm_theta=18.6,target_halfwaveplate=in,target_name=VA1,target_polarization=41.6,target_type=Polarized He-3 270deg
     test
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps8=65535   
    
    EVENTS[0]: 2899         [+]: 1401         [-]: 1451         
    TIME  [0]: 3.570 mins  [+]: 1.751 mins  [-]: 1.752 mins  
    LIVE  [0]:  98.37%      [+]:  98.52%      [-]:  98.31%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]: 8.8/8.8  Hz   T2[0] [PRES/REAL]: 5.0/5.0  Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]: 8.5/8.5  Hz   T2[+] [PRES/REAL]: 5.0/5.0  Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]: 9.0/9.0  Hz   T2[-] [PRES/REAL]: 5.0/5.0  Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:   1879/1879     T2[0] [PRES/REAL]:   1065/1065     T8[0] [PRES/REAL]:      3/219360   
    T1[+] [PRES/REAL]:    898/898      T2[+] [PRES/REAL]:    523/523      T8[+] [PRES/REAL]:      1/107592   
    T1[-] [PRES/REAL]:    949/949      T2[-] [PRES/REAL]:    526/526      T8[-] [PRES/REAL]:      1/107662   
    
    AVERAGE CURRENT
    BCM x1 : -0.0297uA  BCM x3 : -0.0167uA  BCM x10: 0.0001 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :-1.653E+04 ppm     BCM d10:     8516 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-8.399E-07     BCM u3 [0]:-7.875E-06     BCM u10[0]:-8.061E-07     
    BCM u1 [+]:-4.265E-07     BCM u3 [+]:-3.867E-06     BCM u10[+]:-3.959E-07     
    BCM u1 [-]:-4.952E-07     BCM u3 [-]:-3.861E-06     BCM u10[-]:-3.997E-07     
    
    BCM d1 [0]:-1.187E-05     BCM d3 [0]:7.047E-07      BCM d10[0]:8.512E-07      
    BCM d1 [+]:-5.831E-06     BCM d3 [+]:3.444E-07      BCM d10[+]:4.253E-07      
    BCM d1 [-]:-5.824E-06     BCM d3 [-]:3.562E-07      BCM d10[-]:4.183E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 31425 at Wed Sep 12 09:13:29 EDT 2001
    Right Arm D1 momentum : 0
    Right Arm arm angle : 18.603
    Left Arm D1 momentum : 0
    Left Arm arm angle : 18.6014
    Tiefenbach Hall A energy :
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 1706.84
    Right Arm Q1 momentum : 2.26994
    Right Arm Q1 gauss meter : -0.04248
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 976.737
    Right Arm Q2 momentum : 2.26954
    Right Arm Q2 gauss meter : 0.5133
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 318.315
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 1.02025
    Right Arm Q3 power supply current : 903.374
    Right Arm Q3 momentum : 2.2703
    Right Arm Q3 gauss meter : 0.4052
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1707.79
    Left Arm Q1 momentum : 2.27
    Left Arm Q1 gauss meter : -0.14443
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 977.442
    Left Arm Q2 momentum : 2.26995
    Left Arm Q2 gauss meter : 0.5155
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 776.955
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.419681
    Left Arm Q3 power supply current : 903.659
    Left Arm Q3 momentum : 2.26982
    Left Arm Q3 gauss meter : -0.4519
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0226801
    Current on Unser monitor : 5.67703
    Current on Upstream bcm : 0.0225756
    Current on Downstream bcm : 0.0227845
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy : 5738.82
    MBSY1c magnet current (amp) : 239.898
    MBSY1c Bdl : 1.43213e+06
    MBSY3c Hall C Beam energy : 2335.85
    Tiefenbach Hall A energy : 5726.94
    Tiefenbach Hall C energy : 2330.44
    Delta(E)/E width (MV_AI_DXWID) : 2.17348
    IPM1C12.XPOS : -0.00212563
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Right Arm Arm Collimator : 0.865137
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.527832
    HacR_HPE1313A:0_Ch55 : 21.9238
    HacR_HPE1313A:0_Ch54 : -0.822754
    HacR_alignROLL : -0.29286
    HacR_alignPITCH : 0.0589188
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.14209
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 :
    HacL_alignROLL : 0.0697907
    HacL_alignPITCH : 0.143579
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865137
    Left Arm Arm Collimator : 0.868701
    Wien angle : 4.89551
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 112.69
    Wien field : 3.2724
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : ON
    Beam Half-wave plate (off=out) : ON
    OTR x-position : -1.99347
    OTR y-position : -3.84147
    OTR x-width : 2.86101
    OTR y-width : 2.28433
    OTR data valid flag : No
    Polarized 3He Target RTD #1 : 55.4395
    Polarized 3He Target RTD #2 : 43.6621
    Polarized 3He Target RTD #3 : 54.6094
    Polarized 3He Target RTD #4 : 47.4121
    Polarized 3He Target RTD #5 : 47.8516
    Polarized 3He Target RTD #6 : 180.645
    Polarized 3He Target RTD #7 : 172.617
    Polarized 3He Ref. Cell RTD #8 : 46.8945
    Polarized 3He Ref. Cell RTD #9 : -49.7852
    Polarized 3He Ref. Cell RTD #10 : -38.7305
    Polarized 3He Target Ref. Cell Gas Pres. : 4.90196
    Polarized 3He Target Ref. Cell Sys.Vac. : 800.771
    Polarized 3He Target Cooling Jet : 14.3701
    Polarized 3He Target OVEN RTD : 170
    Polarized 3He Target OVEN SP1 SET : 170
    Polarized 3He Target OVEN SP1 : 170
    Polarized 3He Target OVEN AL1 SET : 0
    Polarized 3He Target OVEN AL1 : 150
    Polarized 3He Target OVEN AL1 STATUS : enabled
    Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
    Polarized 3He Target Half-Wave Plate STAT: 1200000
    Polarized 3He Target Position (PA) : -3.6466
    Polarized 3He Target Position (POS) : Empty Target
    Polarized 3He Target Position (DA) : -3.6467
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 0
    Polarized 3He Laser#1 Current : 38
    Polarized 3He Laser#1 Temperature : 14
    Polarized 3He Laser#2 State : 0
    Polarized 3He Laser#2 Current : 37.2
    Polarized 3He Laser#2 Temperature : 22
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 40
    Polarized 3He Laser#3 Temperature : 27.9
    Polarized 3He Laser#4 State : 0
    Polarized 3He Laser#4 Current : 40
    Polarized 3He Laser#4 Temperature : 15.1
    Polarized 3He Laser#5 State : 2
    Polarized 3He Laser#5 Current : 36.5
    Polarized 3He Laser#5 Temperature : 18.1
    Polarized 3He Laser#6 State : 2
    Polarized 3He Laser#6 Current : 40
    Polarized 3He Laser#6 Temperature : 11.3
    Polarized 3He Laser#7 State : 2
    Polarized 3He Laser#7 Current : 36.5
    Polarized 3He Laser#7 Temperature : 19.1
    Polarized 3He Coil Current Longitudinal : -7.016
    Polarized 3He Coil Current Transverse : -0.1189
     
    Parity run number: 3530