Main INDEX
Monthly INDEX
PREV
NEXT
User name ddutta
Log entry time 07:59:35 on September14,2001
Entry number 74518
keyword=Shift Summary
Comments
==============
00:00-4:10 Taking data (270,IN)
04:10 MCC calls to report tripped HV
will take them 15 mins to get beam back.
04:15 MCC says the tripped HV is arcing , they
need to call in experts, which means
no beam for at least an hour.
05:20 MCC reports that the
arcing power supply seems to have damaged the
RF generator, they need another hour or two
to repair.
5:25 Target field rotated to zero degrees
and longitudinal lasers turned on.
Target position changed to BeO.
6:40 Beam back, checking spot on BeO
and raster.
6:42 Move field back to 270
and target position to He3
6:50 -8:00 Taking data again (270,IN)
Run Summary
===========
time run # Good electrons L/R/Total
23:37-00:33 3467/31467 144K/144K/8.49M
00:36-01:31 3468/31468 160K/162K/8.81M
01:34-02:30 3469/31469 154K/155K/9.11M
02:32-03:30 3470/31470 140K/144K/9.39M
03:31-04:12 3471/31471 87K/ 87K/9.57M
06:53-07:48 3475/31475