• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:08:29 on October 16, 2001

    Entry number 74847

    keyword=Start_Run_1153,Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1153 at Tue Oct 16 19:08:15 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.605
    Right Arm Q1 momentum : 1.06606
    Right Arm Q1 gauss meter : 0.020177
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.799
    Right Arm Q2 momentum : 1.06606
    Right Arm Q2 gauss meter : -0.24061
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1.97839
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.344684
    Right Arm Q3 power supply current : 424.194
    Right Arm Q3 momentum : 1.06606
    Right Arm Q3 gauss meter : -0.18964
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 0
    Left Arm Q1 momentum : 0
    Left Arm Q1 gauss meter : 0.000251
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 0.278613
    Left Arm Q2 momentum : 0.000647035
    Left Arm Q2 gauss meter : 0.0010842
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1676.98
    Left Arm D1 momentum : 4.30001
    Left Arm D1 NMR : 1.59323
    Left Arm Q3 power supply current : 1.76003
    Left Arm Q3 momentum : 0.00442088
    Left Arm Q3 gauss meter : 0.0002703
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0704025
    Current on Unser monitor : 6.66789
    Current on Upstream bcm : 0.0623789
    Current on Downstream bcm : 0.0784261
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) :
    Tiefenbach Hall A energy :
    Beam energy : 5738.82
    MBSY1c magnet current (amp) : 0.0377197
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Waterfall Step Motor Position : 0
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0962182
    Waterfall Tachometer : 0.525521
    Waterfall Encoder : 1.15307
    Right Arm Arm Collimator : 0.614893
    Left Arm Arm Collimator : 0.617041
    HacR_HPE1313A:0_Ch58 : -0.515137
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -0.853027
    HacR_alignROLL :
    HacR_alignPITCH :
    HacR_alignHPT :
    HacL_HPE1313A:0_Ch58 : -0.210449
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : 0.102539
    HacL_alignROLL : 0.285927
    HacL_alignPITCH : 0.104903
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle :
    Right Arm Angle Vernier :
    Right Arm Scattering Angle :
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4997
    Laser attenuation Hall A :
    Laser power Hall A :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1