• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:39:38 on October 16, 2001

    Entry number 74852

    keyword=Start_Run_1155,Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1155 at Tue Oct 16 19:39:32 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.605
    Right Arm Q1 momentum : 1.06606
    Right Arm Q1 gauss meter : 0.020191
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.775
    Right Arm Q2 momentum : 1.06601
    Right Arm Q2 gauss meter : -0.24056
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1.97832
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.378832
    Right Arm Q3 power supply current : 424.299
    Right Arm Q3 momentum : 1.06632
    Right Arm Q3 gauss meter : -0.18967
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 0
    Left Arm Q1 momentum : 0
    Left Arm Q1 gauss meter : 0.0002836
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 0.269311
    Left Arm Q2 momentum : 0.000625432
    Left Arm Q2 gauss meter : 0.0010962
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1676.98
    Left Arm D1 momentum : 4.30001
    Left Arm D1 NMR : 1.59322
    Left Arm Q3 power supply current : 1.78556
    Left Arm Q3 momentum : 0.00448499
    Left Arm Q3 gauss meter : 0.0002576
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0717301
    Current on Unser monitor : 5.62339
    Current on Upstream bcm : 0.0640192
    Current on Downstream bcm : 0.079441
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5727
    Beam energy : 5738.82
    MBSY1c magnet current (amp) : 0.0377197
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Waterfall Step Motor Position : 0
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.107428
    Waterfall Tachometer : -0.199588
    Waterfall Encoder : 1.15435
    Right Arm Arm Collimator : 0.614844
    Left Arm Arm Collimator : 0.616992
    HacR_HPE1313A:0_Ch58 : -0.515625
    HacR_HPE1313A:0_Ch55 : 22.4121
    HacR_HPE1313A:0_Ch54 : -0.854492
    HacR_alignROLL : -0.373392
    HacR_alignPITCH : -0.0377394
    HacR_alignHPT : -7.31557
    HacL_HPE1313A:0_Ch58 : -0.209961
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : 0.101562
    HacL_alignROLL : 0.284611
    HacL_alignPITCH : 0.104976
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 56
    Right Arm Angle Vernier : 3.5
    Right Arm Scattering Angle : 56.2667
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4998
    Laser attenuation Hall A :
    Laser power Hall A :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1