Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 12:51:34 on October 22, 2001
Entry number 74907
keyword=End_of_Run_1180
****************************
Run Number: 1180
End of Run Comment:
Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=9999
EVENTS[0]: 3220537 [+]: 1580529 [-]: 1579441
TIME [0]: 1265.548 mins [+]: 620.829 mins [-]: 620.841 mins
LIVE [0]: 179.63% [+]: 179.80% [-]: 179.45%
TRIGGER RATES:
T1[0] [PRES/REAL]:10.0/10.0 Hz T2[0] [PRES/REAL]:13.5/13.5 Hz T8[0] [PRES/REAL]: 0.1/1024.0 Hz
T1[+] [PRES/REAL]:10.0/10.0 Hz T2[+] [PRES/REAL]:13.5/13.5 Hz T8[+] [PRES/REAL]: 0.1/1024.0 Hz
T1[-] [PRES/REAL]:10.0/10.0 Hz T2[-] [PRES/REAL]:13.5/13.5 Hz T8[-] [PRES/REAL]: 0.1/1024.0 Hz
TRIGGER TOTALS:
T1[0] [PRES/REAL]: 760337/760337 T2[0] [PRES/REAL]:1024761/1024761 T8[0] [PRES/REAL]: 7776/77755245
T1[+] [PRES/REAL]: 373069/373069 T2[+] [PRES/REAL]: 502157/502157 T8[+] [PRES/REAL]: 3814/38143724
T1[-] [PRES/REAL]: 372868/372868 T2[-] [PRES/REAL]: 503458/503458 T8[-] [PRES/REAL]: 3814/38144467
AVERAGE CURRENT
BCM x1 : 0.0022 uA BCM x3 : 0.0234 uA BCM x10: 0.0381 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.399E+04 ppm BCM u3 :1.342E+04 ppm BCM u10: 697.4 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1763 ppm BCM d10: 456.4 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001054 BCM u3 [0]:0.0004483 BCM u10[0]:0.002454
BCM u1 [+]:0.0005085 BCM u3 [+]:0.0002237 BCM u10[+]:0.001204
BCM u1 [-]:0.0004944 BCM u3 [-]:0.0002177 BCM u10[-]:0.001203
BCM d1 [0]:-0.0007123 BCM d3 [0]:0.003106 BCM d10[0]:0.003334
BCM d1 [+]:-0.0003482 BCM d3 [+]:0.001531 BCM d10[+]:0.00164
BCM d1 [-]:-0.0003678 BCM d3 [-]:0.001526 BCM d10[-]:0.001638
****************************
End-of-run EPICS data for Run Number 1180 at Mon Oct 22 12:51:10 EDT 2001
Right Arm D1 momentum : 0
Right Arm arm angle :
Left Arm D1 momentum : 4.1
Left Arm arm angle : 12.4998
Tiefenbach Hall A energy :
Right Arm arm mispointing (HPT) :
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity : disabled
Right Arm Q2 power supply current :
Right Arm Q2 momentum :
Right Arm Q2 gauss meter :
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current :
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.389935
Right Arm Q3 power supply current :
Right Arm Q3 momentum :
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3085.15
Left Arm Q1 momentum : 4.10078
Left Arm Q1 gauss meter : -0.26068
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1765.43
Left Arm Q2 momentum : 4.09994
Left Arm Q2 gauss meter : 0.9292
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1555.98
Left Arm D1 momentum : 4.1
Left Arm D1 NMR : 1.51901
Left Arm Q3 power supply current : 1632.3
Left Arm Q3 momentum : 4.10002
Left Arm Q3 gauss meter : -0.8165
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0382775
Current on Unser monitor : 6.38408
Current on Upstream bcm : 0.0289326
Current on Downstream bcm : 0.0478213
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) :
MBSY1c Hall A Beam energy : 5738.83
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.43213e+06
MBSY3c Hall C Beam energy : 2335.85
Tiefenbach Hall A energy : 5727
Tiefenbach Hall C energy : 2330.32
Delta(E)/E width (MV_AI_DXWID) : 2.66292
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.139189
Waterfall Tachometer : -0.199588
Waterfall Encoder : 1.10543
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPE1313A:0_Ch58 : -0.511719
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.842773
HacR_alignROLL :
HacR_alignPITCH :
HacR_alignHPT :
HacL_HPE1313A:0_Ch58 : -0.209473
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : 0.0981445
HacL_alignROLL : 0.282376
HacL_alignPITCH : 0.106362
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.614844
Left Arm Arm Collimator : 0.616992
Laser attenuation Hall A :
Laser power Hall A :
OTR x-position : -6.7914
OTR y-position : 3.57362
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.111165
Waterfall Tachometer : 0.525521
Waterfall Encoder : 1.10573