• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:58:37 on October 22, 2001

    Entry number 74908

    keyword=Start_Run_1181,Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=test withrich configuration, should give the same results as cosmics,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1181 at Mon Oct 22 12:58:30 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=9999
    Right Arm Q1 power supply current : 0
    Right Arm Q1 momentum : 0
    Right Arm Q1 gauss meter : 0.0001172
    Right Arm Q1 power supply polarity : disabled
    Right Arm Q2 power supply current : 0.266362
    Right Arm Q2 momentum : 0.000618918
    Right Arm Q2 gauss meter : -0.0005783
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1.65226
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.360631
    Right Arm Q3 power supply current : 0.0905366
    Right Arm Q3 momentum : 0.000227531
    Right Arm Q3 gauss meter : -0.0002549
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3085.04
    Left Arm Q1 momentum : 4.10064
    Left Arm Q1 gauss meter : -0.26069
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1765.45
    Left Arm Q2 momentum : 4.09998
    Left Arm Q2 gauss meter : 0.9291
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1555.98
    Left Arm D1 momentum : 4.1
    Left Arm D1 NMR : 1.51901
    Left Arm Q3 power supply current : 1632.16
    Left Arm Q3 momentum : 4.09969
    Left Arm Q3 gauss meter : -0.8164
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0380837
    Current on Unser monitor : 5.81026
    Current on Upstream bcm : 0.0290109
    Current on Downstream bcm : 0.0471564
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5727
    Beam energy : 5738.83
    MBSY1c magnet current (amp) : 0
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Waterfall Step Motor Position : -590016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.11677
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.10534
    Right Arm Arm Collimator : 0.614795
    Left Arm Arm Collimator : 0.617041
    HacR_HPE1313A:0_Ch58 : -0.511719
    HacR_HPE1313A:0_Ch55 : 22.7539
    HacR_HPE1313A:0_Ch54 : -0.843262
    HacR_alignROLL : 0
    HacR_alignPITCH : 0
    HacR_alignHPT : 0
    HacL_HPE1313A:0_Ch58 : -0.208984
    HacL_HPE1313A:0_Ch55 : 24.2188
    HacL_HPE1313A:0_Ch54 : 0.0991211
    HacL_alignROLL : 0.282376
    HacL_alignPITCH : 0.106362
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4998
    Laser attenuation Hall A :
    Laser power Hall A :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1