    User name a-onl

    Log entry time 16:48:28 on October 22, 2001

    Entry number 74917

    keyword=End_of_Run_1184
    ****************************
     Run Number: 1184
     End of Run Comment:
    Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=test withrich configuration, should give the same results as cosmics,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=9999   
    
    EVENTS[0]: 17966        [+]: 8822         [-]: 8798         
    TIME  [0]: 10.272 mins  [+]: 5.040 mins  [-]: 5.039 mins  
    LIVE  [0]: 122.95%      [+]: 123.92%      [-]: 122.02%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:10.1/10.1 Hz   T2[0] [PRES/REAL]:13.5/13.5 Hz   T8[0] [PRES/REAL]: 0.1/1024.0 Hz   
    T1[+] [PRES/REAL]: 9.9/9.9  Hz   T2[+] [PRES/REAL]:13.5/13.5 Hz   T8[+] [PRES/REAL]: 0.1/1024.0 Hz   
    T1[-] [PRES/REAL]:10.2/10.2 Hz   T2[-] [PRES/REAL]:13.5/13.5 Hz   T8[-] [PRES/REAL]: 0.1/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:   6207/6207     T2[0] [PRES/REAL]:   8343/8343     T8[0] [PRES/REAL]:     63/631117   
    T1[+] [PRES/REAL]:   2992/2992     T2[+] [PRES/REAL]:   4097/4097     T8[+] [PRES/REAL]:     30/309643   
    T1[-] [PRES/REAL]:   3093/3093     T2[-] [PRES/REAL]:   4087/4087     T8[-] [PRES/REAL]:     30/309625   
    
    AVERAGE CURRENT
    BCM x1 : -0.0151uA  BCM x3 : 0.0057 uA  BCM x10: 0.0204 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :6.364E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:     1818 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :     6163 ppm     BCM d10:     1281 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.678E-06      BCM u3 [0]:-2.151E-06     BCM u10[0]:1.415E-05      
    BCM u1 [+]:1.234E-06      BCM u3 [+]:-1.022E-06     BCM u10[+]:6.953E-06      
    BCM u1 [-]:1.086E-06      BCM u3 [-]:-1.072E-06     BCM u10[-]:6.928E-06      
    
    BCM d1 [0]:-2.13E-05      BCM d3 [0]:9.151E-06      BCM d10[0]:1.103E-05      
    BCM d1 [+]:-1.032E-05     BCM d3 [+]:4.549E-06      BCM d10[+]:5.444E-06      
    BCM d1 [-]:-1.05E-05      BCM d3 [-]:4.493E-06      BCM d10[-]:5.43E-06       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1184 at Mon Oct 22 16:48:16 EDT 2001
    Right Arm D1 momentum : 1
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 3.79756
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 5727
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 751.835
    Right Arm Q1 momentum : 0.999867
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 430.467
    Right Arm Q2 momentum : 1.00023
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 343.927
    Right Arm D1 momentum : 1
    Right Arm D1 NMR : 0.371088
    Right Arm Q3 power supply current : 397.987
    Right Arm Q3 momentum : 1.0002
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3085.04
    Left Arm Q1 momentum : 4.10064
    Left Arm Q1 gauss meter : -0.26074
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1765.49
    Left Arm Q2 momentum : 4.10007
    Left Arm Q2 gauss meter : 0.9292
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1401.25
    Left Arm D1 momentum : 3.80539
    Left Arm D1 NMR : 1.40969
    Left Arm Q3 power supply current : 1632.29
    Left Arm Q3 momentum : 4.1
    Left Arm Q3 gauss meter : -0.8167
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0430026
    Current on Unser monitor : 6.09213
    Current on Upstream bcm : 0.0491941
    Current on Downstream bcm : 0.0368111
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5738.83
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 1.43213e+06
    MBSY3c Hall C Beam energy : 2335.85
    Tiefenbach Hall A energy : 5727
    Tiefenbach Hall C energy : 2330.32
    Delta(E)/E width (MV_AI_DXWID) : 2.7231
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : -590016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0775351
    Waterfall Tachometer : 0.283818
    Waterfall Encoder : 1.10514
    Right Arm Arm Collimator : 0.614844
    Left Arm Arm Collimator : 0.617041
    HacR_HPE1313A:0_Ch58 : -0.509277
    HacR_HPE1313A:0_Ch55 : 22.9492
    HacR_HPE1313A:0_Ch54 : -0.84082
    HacR_alignROLL : -0.359887
    HacR_alignPITCH : -0.0443791
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.208008
    HacL_HPE1313A:0_Ch55 : 24.3164
    HacL_HPE1313A:0_Ch54 : 0.0996094
    HacL_alignROLL : 0.283543
    HacL_alignPITCH : 0.107892
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.614746
    Left Arm Arm Collimator : 0.61709
    Laser attenuation Hall A :
    Laser power Hall A :
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : -590016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0326955
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.10524