    User name a-onl

    Log entry time 16:48:53 on October 22, 2001

    Entry number 74918

    keyword=Start_Run_1185,Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=test withrich configuration, should give the same results as cosmics,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1185 at Mon Oct 22 16:48:46 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=9999
    Right Arm Q1 power supply current : 751.835
    Right Arm Q1 momentum : 0.999867
    Right Arm Q1 gauss meter : 0.018962
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 430.321
    Right Arm Q2 momentum : 0.999892
    Right Arm Q2 gauss meter : -0.22569
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 343.919
    Right Arm D1 momentum : 0.999998
    Right Arm D1 NMR : 0.371087
    Right Arm Q3 power supply current : 397.76
    Right Arm Q3 momentum : 0.999626
    Right Arm Q3 gauss meter : -0.178
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3085.04
    Left Arm Q1 momentum : 4.10064
    Left Arm Q1 gauss meter : -0.26073
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1765.46
    Left Arm Q2 momentum : 4.09999
    Left Arm Q2 gauss meter : 0.9292
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1363.07
    Left Arm D1 momentum : 3.74871
    Left Arm D1 NMR : 1.38866
    Left Arm Q3 power supply current : 1632.15
    Left Arm Q3 momentum : 4.09965
    Left Arm Q3 gauss meter : -0.8167
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0430765
    Current on Unser monitor : 6.67342
    Current on Upstream bcm : 0.0492641
    Current on Downstream bcm : 0.0369113
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5727
    Beam energy : 5738.83
    MBSY1c magnet current (amp) : 0
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Waterfall Step Motor Position : -590016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0756667
    Waterfall Tachometer : 1.49233
    Waterfall Encoder : 1.10612
    Right Arm Arm Collimator : 0.614795
    Left Arm Arm Collimator : 0.617041
    HacR_HPE1313A:0_Ch58 : -0.510254
    HacR_HPE1313A:0_Ch55 : 22.8516
    HacR_HPE1313A:0_Ch54 : -0.84082
    HacR_alignROLL : -0.359509
    HacR_alignPITCH : -0.0442449
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.20752
    HacL_HPE1313A:0_Ch55 : 24.2676
    HacL_HPE1313A:0_Ch54 : 0.0991211
    HacL_alignROLL : 0.283464
    HacL_alignPITCH : 0.107819
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 56
    Right Arm Angle Vernier : 3.5
    Right Arm Scattering Angle : 56.2172
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4998
    Laser attenuation Hall A :
    Laser power Hall A :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1