User name a-onl
Log entry time 18:43:05 on October 22, 2001
Entry number 74920
keyword=Start_Run_1186,Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
Beginning-of-run EPICS data for Run Number 1186 at Mon Oct 22 18:42:59 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=9999
Right Arm Q1 power supply current : 751.835
Right Arm Q1 momentum : 0.999867
Right Arm Q1 gauss meter : 0.01895
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 430.351
Right Arm Q2 momentum : 0.999962
Right Arm Q2 gauss meter : -0.22571
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 343.929
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.871
Right Arm Q3 momentum : 0.999906
Right Arm Q3 gauss meter : -0.17796
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3085.04
Left Arm Q1 momentum : 4.10064
Left Arm Q1 gauss meter : -0.26073
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1765.47
Left Arm Q2 momentum : 4.10002
Left Arm Q2 gauss meter : 0.9292
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1555.75
Left Arm D1 momentum : 4.09998
Left Arm D1 NMR : 1.519
Left Arm Q3 power supply current : 1632.27
Left Arm Q3 momentum : 4.09995
Left Arm Q3 gauss meter : -0.8167
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0462771
Current on Unser monitor : 6.33729
Current on Upstream bcm : 0.0580763
Current on Downstream bcm : 0.0348864
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5727
Beam energy : 5738.83
MBSY1c magnet current (amp) : 0
Arc1 dp/p : 0
Arc2 dp/p : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.109296
Waterfall Tachometer : 5.84298
Waterfall Encoder : 1.10573
Right Arm Arm Collimator : 0.614795
Left Arm Arm Collimator : 0.61709
HacR_HPE1313A:0_Ch58 : -0.509766
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.839844
HacR_alignROLL : -0.358958
HacR_alignPITCH : -0.0434141
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.207031
HacL_HPE1313A:0_Ch55 : 24.3652
HacL_HPE1313A:0_Ch54 : 0.0991211
HacL_alignROLL : 0.283237
HacL_alignPITCH : 0.108475
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4998
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1