Log entry time 17:57:02 on October 23, 2001
Entry number 74931
keyword=End_of_Run_1193
****************************
Run Number: 1193
End of Run Comment:
Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=cosmics with rich,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=TEST,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=9999
EVENTS[0]: 10161 [+]: 4929 [-]: 5016
TIME [0]: 5.708 mins [+]: 2.800 mins [-]: 2.800 mins
LIVE [0]: 123.93% [+]: 125.23% [-]: 122.55%
TRIGGER RATES:
T1[0] [PRES/REAL]:10.3/10.3 Hz T2[0] [PRES/REAL]:13.5/13.5 Hz T8[0] [PRES/REAL]: 0.1/1024.0 Hz
T1[+] [PRES/REAL]:10.1/10.1 Hz T2[+] [PRES/REAL]:13.2/13.2 Hz T8[+] [PRES/REAL]: 0.1/1024.0 Hz
T1[-] [PRES/REAL]:10.6/10.6 Hz T2[-] [PRES/REAL]:13.7/13.7 Hz T8[-] [PRES/REAL]: 0.1/1024.0 Hz
TRIGGER TOTALS:
T1[0] [PRES/REAL]: 3540/3540 T2[0] [PRES/REAL]: 4624/4624 T8[0] [PRES/REAL]: 35/350670
T1[+] [PRES/REAL]: 1695/1695 T2[+] [PRES/REAL]: 2224/2224 T8[+] [PRES/REAL]: 17/172015
T1[-] [PRES/REAL]: 1776/1776 T2[-] [PRES/REAL]: 2300/2300 T8[-] [PRES/REAL]: 17/172034
AVERAGE CURRENT
BCM x1 : -0.0025uA BCM x3 : 0.0192 uA BCM x10: 0.0343 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.209E+04 ppm BCM u3 : 3746 ppm BCM u10: 556.8 ppm
BCM d1 : 1E+39 ppm BCM d3 : 4950 ppm BCM d10: 249.4 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:6.551E-06 BCM u3 [0]:4E-06 BCM u10[0]:1.331E-05
BCM u1 [+]:3.188E-06 BCM u3 [+]:1.988E-06 BCM u10[+]:6.543E-06
BCM u1 [-]:3.112E-06 BCM u3 [-]:1.973E-06 BCM u10[-]:6.536E-06
BCM d1 [0]:-8.248E-06 BCM d3 [0]:9.133E-06 BCM d10[0]:1.021E-05
BCM d1 [+]:-4.044E-06 BCM d3 [+]:4.522E-06 BCM d10[+]:5.026E-06
BCM d1 [-]:-4.132E-06 BCM d3 [-]:4.478E-06 BCM d10[-]:5.024E-06
****************************
End-of-run EPICS data for Run Number 1193 at Tue Oct 23 17:56:51 EDT 2001
Right Arm D1 momentum : 1
Right Arm arm angle : 56.2172
Left Arm D1 momentum : 0.996992
Left Arm arm angle : 12.4997
Tiefenbach Hall A energy : 4622.17
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 430.194
Right Arm Q2 momentum : 0.999597
Right Arm Q2 gauss meter :
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 344.014
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371089
Right Arm Q3 power supply current : 397.887
Right Arm Q3 momentum : 0.999944
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 752.01
Left Arm Q1 momentum : 0.999573
Left Arm Q1 gauss meter : -0.06366
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 430.575
Left Arm Q2 momentum : 0.999943
Left Arm Q2 gauss meter : 0.22662
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 332.535
Left Arm D1 momentum : 0.996991
Left Arm D1 NMR : 0.369117
Left Arm Q3 power supply current : 397.934
Left Arm Q3 momentum : 0.999537
Left Arm Q3 gauss meter : -0.19914
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.062629
Current on Unser monitor : 6.01051
Current on Upstream bcm : 0.0691192
Current on Downstream bcm : 0.0561388
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 4631.65
MBSY1c magnet current (amp) : 193.21
MBSY1c Bdl : 1.15583e+06
MBSY3c Hall C Beam energy : 3493.3
Tiefenbach Hall A energy : 4622.17
Tiefenbach Hall C energy : 3483.86
Delta(E)/E width (MV_AI_DXWID) : 2.70286
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.109296
Waterfall Tachometer : 0.0421149
Waterfall Encoder : 1.10475
Right Arm Arm Collimator : 0.614795
Left Arm Arm Collimator : 0.616992
HacR_HPE1313A:0_Ch58 : -0.506348
HacR_HPE1313A:0_Ch55 : 23.3398
HacR_HPE1313A:0_Ch54 : -0.832031
HacR_alignROLL : -0.350551
HacR_alignPITCH : -0.04761
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.20459
HacL_HPE1313A:0_Ch55 : 24.9023
HacL_HPE1313A:0_Ch54 : 0.103027
HacL_alignROLL : 0.288599
HacL_alignPITCH : 0.111319
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.614795
Left Arm Arm Collimator : 0.617041
OTR x-position : -6.7914
OTR y-position : 3.57362
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.08314
Waterfall Tachometer : 1.73404
Waterfall Encoder : 1.10534