Log entry time 08:36:02 on October 25, 2001
Entry number 74970
keyword=Start_Run_1203,Run_type=cosmics,beam_energy=0,beam_raster=off,comment_text=cosmics, shower counter HV changed (tmp),daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Empty
Beginning-of-run EPICS data for Run Number 1203 at Thu Oct 25 08:35:57 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=9999
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 0.0001081
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.805
Right Arm Q2 momentum : 1.06608
Right Arm Q2 gauss meter : -0.2417
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.747
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current : 424.156
Right Arm Q3 momentum : 1.06596
Right Arm Q3 gauss meter : -0.1904
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3099.56
Left Arm Q1 momentum : 4.11995
Left Arm Q1 gauss meter : -0.26178
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.09
Left Arm Q2 momentum : 4.12005
Left Arm Q2 gauss meter : 0.9334
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1567.81
Left Arm D1 momentum : 4.11999
Left Arm D1 NMR : 1.52643
Left Arm Q3 power supply current : 1640.24
Left Arm Q3 momentum : 4.11998
Left Arm Q3 gauss meter : -0.8203
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0667237
Current on Unser monitor : 6.2706
Current on Upstream bcm : 0.0749639
Current on Downstream bcm : 0.0584836
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 4617.89
Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
Arc1 dp/p : 0
Arc2 dp/p : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.114901
Waterfall Tachometer : 1.25063
Waterfall Encoder : 1.10553
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616943
HacR_HPE1313A:0_Ch58 : -0.504883
HacR_HPE1313A:0_Ch55 : 23.7305
HacR_HPE1313A:0_Ch54 : -0.831055
HacR_alignROLL : -0.349711
HacR_alignPITCH : -0.0489112
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.206543
HacL_HPE1313A:0_Ch55 : 25.2441
HacL_HPE1313A:0_Ch54 : 0.0942383
HacL_alignROLL : 0.27993
HacL_alignPITCH : 0.110158
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4998
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1