• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:59:06 on October 25, 2001

    Entry number 74991

    keyword=End_of_Run_1209
    ****************************
     Run Number: 1209
     End of Run Comment:
    Run_type=harp,beam_energy=4627,beam_raster=off,comment_text=HARP, beam position 0,1 beam spot 0.05x0.07mm**2,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=BeO
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=4   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 81584        [+]: 39984        [-]: 40178        
    TIME  [0]: 1.007 mins  [+]: 0.495 mins  [-]: 0.494 mins  
    LIVE  [0]: 205.18%      [+]: 205.29%      [-]: 205.05%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:625.6/625.6 Hz   T2[0] [PRES/REAL]:32.7/32.7 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:624.4/624.4 Hz   T2[+] [PRES/REAL]:31.7/31.7 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:626.9/626.9 Hz   T2[-] [PRES/REAL]:34.0/34.0 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:  37787/37787    T2[0] [PRES/REAL]:   1976/1976     T8[0] [PRES/REAL]:      0/61846    
    T1[+] [PRES/REAL]:  18535/18535    T2[+] [PRES/REAL]:    942/942      T8[+] [PRES/REAL]:      0/30398    
    T1[-] [PRES/REAL]:  18585/18585    T2[-] [PRES/REAL]:   1009/1009     T8[-] [PRES/REAL]:      0/30356    
    
    AVERAGE CURRENT
    BCM x1 : 3.6059 uA  BCM x3 : 3.6371 uA  BCM x10: 3.6553 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -6239 ppm     BCM u3 :    -6101 ppm     BCM u10:    -6158 ppm     
    BCM d1 :    -6221 ppm     BCM d3 :    -5950 ppm     BCM d10:    -6100 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0002165      BCM u3 [0]:0.0002168      BCM u10[0]:0.0002187      
    BCM u1 [+]:0.0001057      BCM u3 [+]:0.0001059      BCM u10[+]:0.0001068      
    BCM u1 [-]:0.0001069      BCM u3 [-]:0.000107       BCM u10[-]:0.000108       
    
    BCM d1 [0]:0.0002191      BCM d3 [0]:0.0002225      BCM d10[0]:0.0002228      
    BCM d1 [+]:0.000107       BCM d3 [+]:0.0001087      BCM d10[+]:0.0001088      
    BCM d1 [-]:0.0001082      BCM d3 [-]:0.0001098      BCM d10[-]:0.00011        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1209 at Thu Oct 25 22:58:57 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.95
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.605
    Right Arm Q1 momentum : 1.06606
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.622
    Right Arm Q2 momentum : 1.06565
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.745
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.13
    Right Arm Q3 momentum : 1.0659
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.74
    Left Arm Q1 momentum : 4.12018
    Left Arm Q1 gauss meter : -0.26176
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.1
    Left Arm Q2 momentum : 4.12007
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.84
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.38
    Left Arm Q3 momentum : 4.12032
    Left Arm Q3 gauss meter : -0.8203
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 5.16534
    Current on Unser monitor : 11.7508
    Current on Upstream bcm : 5.09622
    Current on Downstream bcm : 5.23447
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 5.25233
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3477.88
    Delta(E)/E width (MV_AI_DXWID) : 1.15737
    IPM1C12.XPOS : 0.00850037
    IPM1H04A.XPOS : -0.173525
    IPM1H04A.YPOS : -1.14603
    IPM1H04B.XPOS : -0.051564
    IPM1H04B.YPOS : -1.03
    Waterfall Step Motor Position : 1.33485e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0812717
    Waterfall Tachometer : 1.73404
    Waterfall Encoder : 1.26845
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.504395
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.830078
    HacR_alignROLL : -0.348116
    HacR_alignPITCH : -0.0499438
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.206055
    HacL_HPE1313A:0_Ch55 : 25.3906
    HacL_HPE1313A:0_Ch54 : 0.0927734
    HacL_alignROLL : 0.278771
    HacL_alignPITCH : 0.110815
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 1.33485e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0812717
    Waterfall Tachometer : 1.73404
    Waterfall Encoder : 1.26864