    User name a-onl

    Log entry time 23:25:19 on October 25, 2001

    Entry number 74997

    keyword=End_of_Run_1211
    ****************************
     Run Number: 1211
     End of Run Comment:
    Run_type=harp,beam_energy=4627,beam_raster=off,comment_text=HARP, beam position 1,0 beam spot 0.05x0.07mm**2,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=BeO
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=4   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 88099        [+]: 42978        [-]: 43439        
    TIME  [0]: 0.754 mins  [+]: 0.370 mins  [-]: 0.370 mins  
    LIVE  [0]: 205.16%      [+]: 204.87%      [-]: 205.45%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:909.7/909.7 Hz   T2[0] [PRES/REAL]:40.0/40.0 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:905.7/905.7 Hz   T2[+] [PRES/REAL]:40.3/40.3 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:912.8/912.8 Hz   T2[-] [PRES/REAL]:39.8/39.8 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:  41132/41132    T2[0] [PRES/REAL]:   1809/1809     T8[0] [PRES/REAL]:      0/46299    
    T1[+] [PRES/REAL]:  20085/20085    T2[+] [PRES/REAL]:    893/893      T8[+] [PRES/REAL]:      0/22709    
    T1[-] [PRES/REAL]:  20259/20259    T2[-] [PRES/REAL]:    884/884      T8[-] [PRES/REAL]:      0/22727    
    
    AVERAGE CURRENT
    BCM x1 : 5.3264 uA  BCM x3 : 5.3631 uA  BCM x10: 5.3830 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -6084 ppm     BCM u3 :    -5903 ppm     BCM u10:    -5941 ppm     
    BCM d1 :    -6072 ppm     BCM d3 :    -5782 ppm     BCM d10:    -5911 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0002389      BCM u3 [0]:0.0002396      BCM u10[0]:0.000241       
    BCM u1 [+]:0.0001164      BCM u3 [+]:0.0001168      BCM u10[+]:0.0001175      
    BCM u1 [-]:0.0001179      BCM u3 [-]:0.0001183      BCM u10[-]:0.000119       
    
    BCM d1 [0]:0.0002428      BCM d3 [0]:0.0002454      BCM d10[0]:0.0002457      
    BCM d1 [+]:0.0001183      BCM d3 [+]:0.0001197      BCM d10[+]:0.0001198      
    BCM d1 [-]:0.0001199      BCM d3 [-]:0.0001212      BCM d10[-]:0.0001213      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1211 at Thu Oct 25 23:25:03 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.702
    Right Arm Q2 momentum : 1.06584
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.746
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.16
    Right Arm Q3 momentum : 1.06597
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.67
    Left Arm Q1 momentum : 4.12008
    Left Arm Q1 gauss meter : -0.26178
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.01
    Left Arm Q2 momentum : 4.11985
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.84
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.15
    Left Arm Q3 momentum : 4.11941
    Left Arm Q3 gauss meter : -0.8202
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 5.12413
    Current on Unser monitor : 11.0635
    Current on Upstream bcm : 5.08486
    Current on Downstream bcm : 5.16341
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 5.15172
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3477.49
    Delta(E)/E width (MV_AI_DXWID) : 1.1553
    IPM1C12.XPOS : 0.00491285
    IPM1H04A.XPOS :
    IPM1H04A.YPOS : -0.176529
    IPM1H04B.XPOS : 1.0677
    IPM1H04B.YPOS : -0.0277963
    Waterfall Step Motor Position : 1.33485e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.114901
    Waterfall Tachometer : 1.25063
    Waterfall Encoder : 1.26884
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.504883
    HacR_HPE1313A:0_Ch55 : 23.6816
    HacR_HPE1313A:0_Ch54 : -0.830078
    HacR_alignROLL : -0.348174
    HacR_alignPITCH : -0.0498766
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.206055
    HacL_HPE1313A:0_Ch55 : 25.3418
    HacL_HPE1313A:0_Ch54 : 0.0927734
    HacL_alignROLL : 0.279237
    HacL_alignPITCH : 0.111252
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 1.33485e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.120506
    Waterfall Tachometer : 0.283818
    Waterfall Encoder : 1.26835