    User name a-onl

    Log entry time 04:38:27 on October 26, 2001

    Entry number 75036

    keyword=End_of_Run_1223
    ****************************
     Run Number: 1223
     End of Run Comment:
    Run_type=other,beam_energy=4627,beam_raster=off,comment_text=,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Waterfall
     Deadtime was 25%, too high.  Adjust ps factors for next run.
    
    PRESCALE FACTORS:ps1=75   ps2=6   ps3=480   ps4=50   ps5=1   ps8=65535   
    
    EVENTS[0]: 426274       [+]: 208297       [-]: 209759       
    TIME  [0]: 4.514 mins  [+]: 2.215 mins  [-]: 2.214 mins  
    LIVE  [0]: 250.55%      [+]: 251.40%      [-]: 249.51%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:460.0/34497.9 Hz   T2[0] [PRES/REAL]:168.2/1009.4 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:456.0/34202.6 Hz   T2[+] [PRES/REAL]:167.3/1003.8 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:463.9/34790.1 Hz   T2[-] [PRES/REAL]:169.0/1014.1 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]: 124570/9342755  T2[0] [PRES/REAL]:  45562/273375   T8[0] [PRES/REAL]:      4/277321   
    T1[+] [PRES/REAL]:  60616/4546245  T2[+] [PRES/REAL]:  22237/133427   T8[+] [PRES/REAL]:      2/136111   
    T1[-] [PRES/REAL]:  61616/4621267  T2[-] [PRES/REAL]:  22451/134709   T8[-] [PRES/REAL]:      2/136021   
    
    AVERAGE CURRENT
    BCM x1 : 36.5695uA  BCM x3 : 36.6844uA  BCM x10: 36.6280uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -5381 ppm     BCM u3 :    -5231 ppm     BCM u10:    -5052 ppm     
    BCM d1 :    -5381 ppm     BCM d3 :    -5133 ppm     BCM d10:    -5060 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.009785       BCM u3 [0]:0.009837       BCM u10[0]:0.009826       
    BCM u1 [+]:0.004777       BCM u3 [+]:0.004803       BCM u10[+]:0.004798       
    BCM u1 [-]:0.004825       BCM u3 [-]:0.00485        BCM u10[-]:0.004844       
    
    BCM d1 [0]:0.01002        BCM d3 [0]:0.01003        BCM d10[0]:0.01001        
    BCM d1 [+]:0.004893       BCM d3 [+]:0.004899       BCM d10[+]:0.00489        
    BCM d1 [-]:0.004942       BCM d3 [-]:0.004946       BCM d10[-]:0.004936       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1223 at Fri Oct 26 04:38:19 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.586
    Right Arm Q2 momentum : 1.06557
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.746
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.189
    Right Arm Q3 momentum : 1.06605
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.67
    Left Arm Q1 momentum : 4.12008
    Left Arm Q1 gauss meter : -0.26178
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.06
    Left Arm Q2 momentum : 4.11998
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.84
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.15
    Left Arm Q3 momentum : 4.11976
    Left Arm Q3 gauss meter : -0.8202
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 50.2738
    Current on Unser monitor : 56.0935
    Current on Upstream bcm : 49.6362
    Current on Downstream bcm : 50.9114
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 49.8904
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3477.74
    Delta(E)/E width (MV_AI_DXWID) : 2.18632
    IPM1C12.XPOS : 0.000761718
    IPM1H04A.XPOS : 0.615782
    IPM1H04A.YPOS : 1.13042
    IPM1H04B.XPOS : -0.321699
    IPM1H04B.YPOS : -0.000979737
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3083
    Waterfall Flow Meter : 2.34941
    Waterfall Tachometer : 754.639
    Waterfall Encoder : 1.80797
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    HacR_HPE1313A:0_Ch58 : -0.50293
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.830566
    HacR_alignROLL : -0.34916
    HacR_alignPITCH : -0.0498766
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.205078
    HacL_HPE1313A:0_Ch55 : 25.3418
    HacL_HPE1313A:0_Ch54 : 0.0927734
    HacL_alignROLL : 0.278227
    HacL_alignPITCH : 0.111615
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3083
    Waterfall Flow Meter : 2.38117
    Waterfall Tachometer : 755.605
    Waterfall Encoder : 1.80836