    User name a-onl

    Log entry time 07:53:21 on October 26, 2001

    Entry number 75059

    keyword=End_of_Run_1231
    ****************************
     Run Number: 1231
     End of Run Comment:
    Run_type=other,beam_energy=4627,beam_raster=off,comment_text=current scan of target.  TACH=1200, beam current 20 uA  All ps=1,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 497569       [+]: 246371       [-]: 241924       
    TIME  [0]: 1.749 mins  [+]: 0.858 mins  [-]: 0.858 mins  
    LIVE  [0]:  42.85%      [+]:  43.56%      [-]:  42.16%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:10767.4/10767.4 Hz   T2[0] [PRES/REAL]:298.4/298.4 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:10689.4/10689.4 Hz   T2[+] [PRES/REAL]:297.0/297.0 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:10840.1/10840.1 Hz   T2[-] [PRES/REAL]:299.4/299.4 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:1129820/1129820  T2[0] [PRES/REAL]:  31306/31306    T8[0] [PRES/REAL]:      1/107448   
    T1[+] [PRES/REAL]: 550339/550339   T2[+] [PRES/REAL]:  15293/15293    T8[+] [PRES/REAL]:      0/52720    
    T1[-] [PRES/REAL]: 558341/558341   T2[-] [PRES/REAL]:  15419/15419    T8[-] [PRES/REAL]:      0/52743    
    
    AVERAGE CURRENT
    BCM x1 : 19.3305uA  BCM x3 : 19.4108uA  BCM x10: 19.4440uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -6189 ppm     BCM u3 :    -6025 ppm     BCM u10:    -6062 ppm     
    BCM d1 :    -6203 ppm     BCM d3 :    -5923 ppm     BCM d10:    -6029 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002006       BCM u3 [0]:0.002017       BCM u10[0]:0.002022       
    BCM u1 [+]:0.0009781      BCM u3 [+]:0.0009835      BCM u10[+]:0.000986       
    BCM u1 [-]:0.0009907      BCM u3 [-]:0.0009959      BCM u10[-]:0.0009985      
    
    BCM d1 [0]:0.002051       BCM d3 [0]:0.002057       BCM d10[0]:0.002058       
    BCM d1 [+]:0.0009997      BCM d3 [+]:0.001003       BCM d10[+]:0.001004       
    BCM d1 [-]:0.001013       BCM d3 [-]:0.001015       BCM d10[-]:0.001016       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1231 at Fri Oct 26 07:53:12 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.91
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.71
    Right Arm Q1 momentum : 1.0662
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.796
    Right Arm Q2 momentum : 1.06606
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.746
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.321
    Right Arm Q3 momentum : 1.06638
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.74
    Left Arm Q1 momentum : 4.12018
    Left Arm Q1 gauss meter : -0.26176
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.11
    Left Arm Q2 momentum : 4.12009
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.85
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.29
    Left Arm Q3 momentum : 4.12011
    Left Arm Q3 gauss meter : -0.8202
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 21.0312
    Current on Unser monitor : 27.5006
    Current on Upstream bcm : 20.8894
    Current on Downstream bcm : 21.1525
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 20.8714
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.91
    Tiefenbach Hall C energy : 3477.77
    Delta(E)/E width (MV_AI_DXWID) : 1.76803
    IPM1C12.XPOS : 0.0126676
    IPM1H04A.XPOS : 0.0544003
    IPM1H04A.YPOS : -0.043192
    IPM1H04B.XPOS : 0.111423
    IPM1H04B.YPOS : -0.00415064
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.09254
    Waterfall Tachometer : 1179.31
    Waterfall Encoder : 1.80729
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868604
    HacR_HPE1313A:0_Ch58 : -0.503418
    HacR_HPE1313A:0_Ch55 : 23.7793
    HacR_HPE1313A:0_Ch54 : -0.831055
    HacR_alignROLL : -0.348058
    HacR_alignPITCH : -0.0504601
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.205078
    HacL_HPE1313A:0_Ch55 : 25.3418
    HacL_HPE1313A:0_Ch54 : 0.0917969
    HacL_alignROLL : 0.277762
    HacL_alignPITCH : 0.111615
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868604
    OTR x-position : 1.78351
    OTR y-position : 0.339489
    OTR x-width : 0.119908
    OTR y-width : 0.118661
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.02902
    Waterfall Tachometer : 1231.52
    Waterfall Encoder : 1.80758