    Log entry time 09:16:19 on October 26, 2001

    Entry number 75069

    keyword=End_of_Run_1235
    ****************************
     Run Number: 1235
     End of Run Comment:
    Run_type=other,beam_energy=4627,beam_raster=off,comment_text=current scan of target.  TACH=1200, beam current 60 uA all ps=1,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 533911       [+]: 260666       [-]: 263406       
    TIME  [0]: 6.617 mins  [+]: 3.248 mins  [-]: 3.247 mins  
    LIVE  [0]:  16.17%      [+]:  16.21%      [-]:  16.13%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:8081.6/8081.6 Hz   T2[0] [PRES/REAL]:233.7/233.7 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:8019.3/8019.3 Hz   T2[+] [PRES/REAL]:231.5/231.5 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:8143.6/8143.6 Hz   T2[-] [PRES/REAL]:235.8/235.8 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:3208497/3208497  T2[0] [PRES/REAL]:  92765/92765    T8[0] [PRES/REAL]:      6/406541   
    T1[+] [PRES/REAL]:1562744/1562744  T2[+] [PRES/REAL]:  45104/45104    T8[+] [PRES/REAL]:      3/199550   
    T1[-] [PRES/REAL]:1586665/1586665  T2[-] [PRES/REAL]:  45941/45941    T8[-] [PRES/REAL]:      3/199512   
    
    AVERAGE CURRENT
    BCM x1 : 14.6944uA  BCM x3 : 14.7507uA  BCM x10: 14.5265uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -6888 ppm     BCM u3 :    -6729 ppm     BCM u10:    -5714 ppm     
    BCM d1 :    -6907 ppm     BCM d3 :    -6606 ppm     BCM d10:    -5792 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005768       BCM u3 [0]:0.005797       BCM u10[0]:0.005706       
    BCM u1 [+]:0.002811       BCM u3 [+]:0.002826       BCM u10[+]:0.002785       
    BCM u1 [-]:0.00285        BCM u3 [-]:0.002864       BCM u10[-]:0.002816       
    
    BCM d1 [0]:0.0059         BCM d3 [0]:0.005916       BCM d10[0]:0.005828       
    BCM d1 [+]:0.002875       BCM d3 [+]:0.002884       BCM d10[+]:0.002844       
    BCM d1 [-]:0.002915       BCM d3 [-]:0.002922       BCM d10[-]:0.002877       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1235 at Fri Oct 26 09:16:08 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4618.75
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.881
    Right Arm Q2 momentum : 1.06625
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.752
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.395581
    Right Arm Q3 power supply current : 424.17
    Right Arm Q3 momentum : 1.066
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.74
    Left Arm Q1 momentum : 4.12018
    Left Arm Q1 gauss meter : -0.26178
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.04
    Left Arm Q2 momentum : 4.11993
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.85
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.17
    Left Arm Q3 momentum : 4.1198
    Left Arm Q3 gauss meter : -0.8203
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.08049
    Current on Unser monitor : 5.94057
    Current on Upstream bcm : 0.07302
    Current on Downstream bcm : 0.08796
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4618.75
    Tiefenbach Hall C energy : 3477.77
    Delta(E)/E width (MV_AI_DXWID) : 20.2638
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.07573
    Waterfall Tachometer : 1211.46
    Waterfall Encoder : 1.80817
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.503418
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.830078
    HacR_alignROLL : -0.348667
    HacR_alignPITCH : -0.0507748
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.206055
    HacL_HPE1313A:0_Ch55 : 25.4395
    HacL_HPE1313A:0_Ch54 : 0.0917969
    HacL_alignROLL : 0.276911
    HacL_alignPITCH : 0.110815
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868604
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.05144
    Waterfall Tachometer : 1208.56
    Waterfall Encoder : 1.80464