    User name a-onl

    Log entry time 06:04:35 on October 27, 2001

    Entry number 75157

    keyword=Start_Run_1269,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra. ,daq_mode=both HRS daq,leftarm_p=4.245,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
    Beginning-of-run EPICS data for Run Number 1269 at Sat Oct 27 06:04:28 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=220,ps2=7,ps3=40,ps4=52,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.57
    Right Arm Q1 momentum : 1.06601
    Right Arm Q1 gauss meter : 0.020212
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.849
    Right Arm Q2 momentum : 1.06618
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.384
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.281
    Right Arm Q3 momentum : 1.06628
    Right Arm Q3 gauss meter : -0.19042
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3193.68
    Left Arm Q1 momentum : 4.24504
    Left Arm Q1 gauss meter : -0.26969
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1827.93
    Left Arm Q2 momentum : 4.24507
    Left Arm Q2 gauss meter : 0.9618
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1642.68
    Left Arm D1 momentum : 4.24501
    Left Arm D1 NMR : 1.57282
    Left Arm Q3 power supply current : 1690.09
    Left Arm Q3 momentum : 4.2452
    Left Arm Q3 gauss meter : -0.8454
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 40.137
    Current on Unser monitor : 45.9383
    Current on Upstream bcm : 39.9504
    Current on Downstream bcm : 40.3639
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 40.1007
    Tiefenbach Hall A energy : 4617.93
    Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    Arc1 dp/p : 7.78517e-05
    Arc2 dp/p : -0.00082585
    Waterfall Step Motor Position : 349952
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.107428
    Waterfall Tachometer : 1.25063
    Waterfall Encoder : 1.18317
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.501953
    HacR_HPE1313A:0_Ch55 : 23.8281
    HacR_HPE1313A:0_Ch54 : -0.829102
    HacR_alignROLL : -0.34745
    HacR_alignPITCH : -0.0523912
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.204102
    HacL_HPE1313A:0_Ch55 : 25.4883
    HacL_HPE1313A:0_Ch54 : 0.0893555
    HacL_alignROLL : 0.275673
    HacL_alignPITCH : 0.112272
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 56
    Right Arm Angle Vernier : 3.5
    Right Arm Scattering Angle : 56.2172
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4999
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1