Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 06:41:43 on October 27, 2001
Entry number 75164
keyword=End_of_Run_1271
****************************
Run Number: 1271
End of Run Comment:
Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra. all ps factors 1,daq_mode=both HRS daq,leftarm_p=4.245,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=65535
EVENTS[0]: 1012015 [+]: 496937 [-]: 496238
TIME [0]: 4.621 mins [+]: 2.267 mins [-]: 2.267 mins
LIVE [0]: 8.63% [+]: 8.70% [-]: 8.57%
TRIGGER RATES: PRES/REAL
T1[0] :8847.8/8847.8 Hz T2[0] :263.2/263.2 Hz T3[0] :30954.9/30954.9 Hz T4[0] :2019.5/2019.5 Hz T5[0] :215.7/215.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :8787.5/8787.5 Hz T2[+] :258.7/258.7 Hz T3[+] :30735.3/30735.3 Hz T4[+] :2007.1/2007.1 Hz T5[+] :215.0/215.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :8901.9/8901.9 Hz T2[-] :267.5/267.5 Hz T3[-] :31162.0/31162.0 Hz T4[-] :2030.5/2030.5 Hz T5[-] :216.6/216.6 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :2453096/2453096 T2[0] : 72975/72975 T3[0] :8582355/8582355 T4[0] : 559928/559928 T5[0] : 59813/59813 T8[0] : 4/283908
T1[+] :1195157/1195157 T2[+] : 35180/35180 T3[+] :4180212/4180212 T4[+] : 272978/272978 T5[+] : 29247/29247 T8[+] : 2/139271
T1[-] :1210933/1210933 T2[-] : 36388/36388 T3[-] :4238978/4238978 T4[-] : 276215/276215 T5[-] : 29469/29469 T8[-] : 2/139295
AVERAGE CURRENT
BCM x1 : 30.5580uA BCM x3 : 30.6673uA BCM x10: 30.6997uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -6499 ppm BCM u3 : -6317 ppm BCM u10: -6368 ppm
BCM d1 : -6497 ppm BCM d3 : -6200 ppm BCM d10: -6325 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.008377 BCM u3 [0]:0.008422 BCM u10[0]:0.008437
BCM u1 [+]:0.004082 BCM u3 [+]:0.004105 BCM u10[+]:0.004112
BCM u1 [-]:0.004136 BCM u3 [-]:0.004158 BCM u10[-]:0.004165
BCM d1 [0]:0.008568 BCM d3 [0]:0.008583 BCM d10[0]:0.008587
BCM d1 [+]:0.004175 BCM d3 [+]:0.004184 BCM d10[+]:0.004185
BCM d1 [-]:0.00423 BCM d3 [-]:0.004237 BCM d10[-]:0.004239
****************************
End-of-run EPICS data for Run Number 1271 at Sat Oct 27 06:41:31 EDT 2001
OTR y-width : 0.0328927
Right Arm D1 momentum : 1.066
OTR data valid flag : No
Right Arm arm angle : 56.2172
Waterfall Step Motor Position : 349952
Left Arm D1 momentum : 4.24501
Waterfall Pump Speed : 2048
Left Arm arm angle : 12.4999
Waterfall Flow Meter : -0.150399
Tiefenbach Hall A energy : 4617.94
Waterfall Tachometer : -17.8439
Right Arm arm mispointing (HPT) : -0
Waterfall Encoder : 1.18297
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 801.5
Right Arm Q1 momentum : 1.06592
Right Arm Q1 gauss meter : 0.020212
Right Arm Q1 power supply polarity : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 1
Right Arm Q2 power supply current : 458.852
Right Arm Q2 momentum : 1.06619
ceb00020
499769
1019916
1789640
990040
914949
826235
129
0
1223842
1252093
1373886
1685126
1104430
486
1795429
0
576067
1078625
1260918
934301
877381
729324
97
0
964795
2148455
1584050
1472996
1931059
1893
973797
0
ceb20010
315270
750770
870694
736797
645876
457454
48
0
537683
949732
957679
943538
817872
0
652875
0
ceb30010
0
0
0
0
0
0
0
0
0
0
1649
337
1333
26980
3072219
2888499
ceb50010
1126
1126
141
141
141
141
140
140
844
844
141
141
141
141
140
140
ceb60010
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ceb70020
1238041
35150
51423108
5037372
4156
0
16894177
139160
11464
16873903
53242762
0
499597
5497617
0
5446182
0
0
4176060
0
0
0
0
0
0
0
4160
0
0
0
0
1193637
ceb80020
2539969
72929
105467359
10334412
4156
4154
34647225
283604
23519
34601434
109194110
0
1017410
11277116
0
11171592
0
0
8570729
0
0
0
0
0
0
0
8379
0
0
0
0
2449076
ceb90020
1254092
36373
52063350
5100590
0
4154
17102533
139125
11527
17078144
53900862
0
498890
5567356
0
5515304
0
0
4232489
0
0
0
0
0
0
0
4167
0
0
0
0
1208707
abc00010
1830847
4370816
7544659
3388072
1936244
2027312
3
10043
2330238
4618087
5024305
4159632
2164756
1233321
8
0
abc10010
2768103
5209804
6115027
3020582
3050571
1514483
225
8240
2364858
5074323
4880823
4137788
2683305
1996351
199
0
abc20010
1557602
3667889
4162011
2665549
1736062
1106989
2
3359
1867030
3876585
3987264
3125689
1724915
1019076
2
0
abc30020
1194803
35164
4178927
272872
29236
4158
16906193
139237
51459703
0
16885909
53280619
496937
5501514
11470
5448341
4744856
41644
0
13925921
4161
0
0
139236
4029582
0
272578
0
0
4094236
409
409
abc40020
2451684
72936
8577275
559578
59781
4158
34674757
283778
105551181
4157
34628926
109280874
1012015
11286063
23533
11176936
9650030
84845
0
28562114
8391
0
0
283778
8269586
0
559006
0
0
8402656
847
847
abc50020
1209779
36363
4235010
275962
29441
0
17113166
139195
52095743
4156
17088771
53934367
496238
5570811
11533
5516979
4727593
41614
0
14091256
4167
0
0
139195
4082573
0
275691
0
0
4148435
421
421
abc60010
0
0
0
0
0
0
0
0
0
0
0
10962333
52859910
45977
10824305
10354331
abc70010
1127
1127
141
141
141
141
140
141
847
847
141
141
141
141
140
141
abc80010
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Right Arm Q2 gauss meter : -0.2418
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.376
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.395579
Right Arm Q3 power supply current : 424.071
Right Arm Q3 momentum : 1.06575
Right Arm Q3 gauss meter : -0.19038
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3193.72
Left Arm Q1 momentum : 4.24509
Left Arm Q1 gauss meter : -0.26968
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1828
Left Arm Q2 momentum : 4.24524
Left Arm Q2 gauss meter : 0.9618
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1642.68
Left Arm D1 momentum : 4.24501
Left Arm D1 NMR : 1.57282
Left Arm Q3 power supply current : 1689.98
Left Arm Q3 momentum : 4.24492
Left Arm Q3 gauss meter : -0.8454
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.3492
Current on Unser monitor : 44.1609
Current on Upstream bcm : 39.1054
Current on Downstream bcm : 39.6028
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 39.3461
MBSY1c Hall A Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.29
Tiefenbach Hall A energy : 4617.91
Tiefenbach Hall C energy : 3479.35
Delta(E)/E width (MV_AI_DXWID) : 17.3417
IPM1C12.XPOS : 0.000878662
IPM1H04A.XPOS : -0.0689624
IPM1H04A.YPOS : -0.0824098
IPM1H04B.XPOS : 0.0378903
IPM1H04B.YPOS : -0.0363858
Waterfall Step Motor Position : 349952
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.120506
Waterfall Tachometer : 2.21744
Waterfall Encoder : 1.18307
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868652
HacR_HPE1313A:0_Ch58 : -0.502441
HacR_HPE1313A:0_Ch55 : 23.877
HacR_HPE1313A:0_Ch54 : -0.829102
HacR_alignROLL : -0.347072
HacR_alignPITCH : -0.0527058
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.203613
HacL_HPE1313A:0_Ch55 : 25.5371
HacL_HPE1313A:0_Ch54 : 0.0908203
HacL_alignROLL : 0.276682
HacL_alignPITCH : 0.11322
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868652
OTR x-position : 1.70487
OTR y-position : 0.319123
OTR x-width : 0.0272304
OTR y-width : 0.0200592
OTR data valid flag : No
Waterfall Step Motor Position : 349952
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.107428
Waterfall Tachometer : -9.3843
Waterfall Encoder : 1.18327