Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 00:44:52 on October 28, 2001
Entry number 75252
keyword=End_of_Run_1305
****************************
Run Number: 1305
End of Run Comment:
Run_type=production,beam_energy=4.627,beam_raster=on,comment_text=collimator open on both arms. Beo Target run.,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
PRESCALE FACTORS:ps1=35 ps2=3 ps3=250 ps4=25 ps5=1 ps8=65535
EVENTS[0]: 999327 [+]: 487022 [-]: 493904
TIME [0]: 46.565 mins [+]: 22.851 mins [-]: 22.849 mins
LIVE [0]: 95.04% [+]: 95.05% [-]: 95.05%
TRIGGER RATES: PRES/REAL
T1[0] :86.9/3041.5 Hz T2[0] :41.2/123.7 Hz T3[0] :93.0/23249.2 Hz T4[0] :46.1/1153.2 Hz T5[0] :109.1/109.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :86.3/3020.5 Hz T2[+] :40.9/122.8 Hz T3[+] :92.3/23083.9 Hz T4[+] :45.8/1145.7 Hz T5[+] :108.3/108.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :87.5/3061.9 Hz T2[-] :41.5/124.5 Hz T3[-] :93.6/23409.7 Hz T4[-] :46.4/1160.2 Hz T5[-] :110.0/110.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 242789/8497646 T2[0] : 115201/345604 T3[0] : 259825/64956483 T4[0] : 128879/3221994 T5[0] : 304768/304768 T8[0] : 43/2860976
T1[+] : 118322/4141295 T2[+] : 56137/168413 T3[+] : 126597/31649465 T4[+] : 62832/1570824 T5[+] : 148472/148472 T8[+] : 21/1403965
T1[-] : 119934/4197714 T2[-] : 56900/170700 T3[-] : 128372/32093225 T4[-] : 63624/1590619 T5[-] : 150782/150782 T8[-] : 21/1403840
AVERAGE CURRENT
BCM x1 : 25.8380uA BCM x3 : 25.9358uA BCM x10: 25.9735uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -6541 ppm BCM u3 : -6370 ppm BCM u10: -6421 ppm
BCM d1 : -6548 ppm BCM d3 : -6256 ppm BCM d10: -6379 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.07138 BCM u3 [0]:0.07176 BCM u10[0]:0.07191
BCM u1 [+]:0.0348 BCM u3 [+]:0.03499 BCM u10[+]:0.03506
BCM u1 [-]:0.03525 BCM u3 [-]:0.03544 BCM u10[-]:0.03551
BCM d1 [0]:0.073 BCM d3 [0]:0.07317 BCM d10[0]:0.07322
BCM d1 [+]:0.03559 BCM d3 [+]:0.03568 BCM d10[+]:0.0357
BCM d1 [-]:0.03605 BCM d3 [-]:0.03613 BCM d10[-]:0.03616
****************************
End-of-run EPICS data for Run Number 1305 at Sun Oct 28 00:44:46 EDT 2001
Right Arm D1 momentum : 1.066
Right Arm arm angle : 59.9699
Left Arm D1 momentum : 4.121
Left Arm arm angle : 12.4999
Tiefenbach Hall A energy : 4617.91
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 801.57
Right Arm Q1 momentum : 1.06601
Right Arm Q1 gauss meter : 0.020205
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.912
Right Arm Q2 momentum : 1.06633
Right Arm Q2 gauss meter : -0.2418
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.377
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current : 424.085
Right Arm Q3 momentum : 1.06579
Right Arm Q3 gauss meter : -0.19037
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3100.58
Left Arm Q1 momentum : 4.12129
Left Arm Q1 gauss meter : -0.26191
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.5
Left Arm Q2 momentum : 4.121
Left Arm Q2 gauss meter : 0.9339
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1568.04
Left Arm D1 momentum : 4.121
Left Arm D1 NMR : 1.5268
Left Arm Q3 power supply current : 1640.61
Left Arm Q3 momentum : 4.1209
Left Arm Q3 gauss meter : -0.8207
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 29.3308
Current on Unser monitor : 34.9384
Current on Upstream bcm : 29.0954
Current on Downstream bcm : 29.5662
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.2383
MBSY1c Hall A Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.29
Tiefenbach Hall A energy : 4617.91
Tiefenbach Hall C energy : 3479.2
Delta(E)/E width (MV_AI_DXWID) : 5.10676
IPM1C12.XPOS : 0.00933573
IPM1H04A.XPOS : -0.0498165
IPM1H04A.YPOS : -0.0481469
IPM1H04B.XPOS : 0.0620132
IPM1H04B.YPOS : -0.0112722
Waterfall Step Motor Position : 1.33478e+06
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.109296
Waterfall Tachometer : 1.73404
Waterfall Encoder : 1.26737
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.868701
HacR_HPE1313A:0_Ch58 : -0.478027
HacR_HPE1313A:0_Ch55 : 23.9258
HacR_HPE1313A:0_Ch54 : -0.78418
HacR_alignROLL : -0.301516
HacR_alignPITCH : -0.0744679
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.202148
HacL_HPE1313A:0_Ch55 : 25.5859
HacL_HPE1313A:0_Ch54 : 0.0913086
HacL_alignROLL : 0.277692
HacL_alignPITCH : 0.114605
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.868848
OTR x-position : -0.802433
OTR y-position : -1.39288
OTR x-width : 2.31184
OTR y-width : 1.80117
OTR data valid flag : No
Waterfall Step Motor Position : 1.33478e+06
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.111165
Waterfall Tachometer : 0.767224
Waterfall Encoder : 1.26717