Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 01:15:10 on October 28, 2001
Entry number 75256
keyword=End_of_Run_1307
****************************
Run Number: 1307
End of Run Comment:
Run_type=production,beam_energy=4.627,beam_raster=on,comment_text=collimator open on both arms. Beo Target run.,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
PRESCALE FACTORS:ps1=35 ps2=3 ps3=250 ps4=25 ps5=1 ps8=65535
EVENTS[0]: 998943 [+]: 487458 [-]: 492871
TIME [0]: 43.871 mins [+]: 21.529 mins [-]: 21.527 mins
LIVE [0]: 94.99% [+]: 95.10% [-]: 94.89%
TRIGGER RATES: PRES/REAL
T1[0] :92.3/3232.1 Hz T2[0] :43.6/130.8 Hz T3[0] :98.8/24711.0 Hz T4[0] :49.0/1225.4 Hz T5[0] :115.7/115.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :91.7/3210.0 Hz T2[+] :43.3/129.8 Hz T3[+] :98.2/24543.1 Hz T4[+] :48.6/1215.1 Hz T5[+] :115.0/115.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :93.0/3253.6 Hz T2[-] :43.9/131.7 Hz T3[-] :99.5/24875.9 Hz T4[-] :49.4/1235.1 Hz T5[-] :116.4/116.4 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 243073/8507564 T2[0] : 114726/344179 T3[0] : 260180/65045135 T4[0] : 129023/3225579 T5[0] : 304553/304553 T8[0] : 41/2695411
T1[+] : 118469/4146422 T2[+] : 55904/167713 T3[+] : 126811/31702784 T4[+] : 62782/1569562 T5[+] : 148592/148592 T8[+] : 20/1322721
T1[-] : 120064/4202271 T2[-] : 56715/170146 T3[-] : 128518/32129531 T4[-] : 63812/1595308 T5[-] : 150278/150278 T8[-] : 20/1322592
AVERAGE CURRENT
BCM x1 : 27.4717uA BCM x3 : 27.5743uA BCM x10: 27.6132uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -6409 ppm BCM u3 : -6244 ppm BCM u10: -6298 ppm
BCM d1 : -6419 ppm BCM d3 : -6133 ppm BCM d10: -6257 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0715 BCM u3 [0]:0.07188 BCM u10[0]:0.07203
BCM u1 [+]:0.03486 BCM u3 [+]:0.03505 BCM u10[+]:0.03512
BCM u1 [-]:0.03531 BCM u3 [-]:0.03549 BCM u10[-]:0.03557
BCM d1 [0]:0.07313 BCM d3 [0]:0.07329 BCM d10[0]:0.07334
BCM d1 [+]:0.03566 BCM d3 [+]:0.03574 BCM d10[+]:0.03577
BCM d1 [-]:0.03611 BCM d3 [-]:0.03618 BCM d10[-]:0.03621
****************************
End-of-run EPICS data for Run Number 1307 at Sun Oct 28 01:15:03 EST 2001
Right Arm D1 momentum : 1.066
Right Arm arm angle : 59.9699
Left Arm D1 momentum : 4.121
Left Arm arm angle : 12.4999
Tiefenbach Hall A energy : 4617.93
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 801.43
Right Arm Q1 momentum : 1.06582
Right Arm Q1 gauss meter : 0.020209
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.633
Right Arm Q2 momentum : 1.06568
Right Arm Q2 gauss meter : -0.2417
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.377
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current : 424.324
Right Arm Q3 momentum : 1.06638
Right Arm Q3 gauss meter : -0.19042
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3100.61
Left Arm Q1 momentum : 4.12134
Left Arm Q1 gauss meter : -0.26188
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.4
Left Arm Q2 momentum : 4.12077
Left Arm Q2 gauss meter : 0.934
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1568.04
Left Arm D1 momentum : 4.121
Left Arm D1 NMR : 1.5268
Left Arm Q3 power supply current : 1640.61
Left Arm Q3 momentum : 4.12091
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 29.6948
Current on Unser monitor : 35.3414
Current on Upstream bcm : 29.474
Current on Downstream bcm : 29.9156
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.8574
MBSY1c Hall A Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.29
Tiefenbach Hall A energy : 4617.93
Tiefenbach Hall C energy : 3478.85
Delta(E)/E width (MV_AI_DXWID) : 5.12275
IPM1C12.XPOS : -0.00322196
IPM1H04A.XPOS : -0.0519105
IPM1H04A.YPOS : -0.0558088
IPM1H04B.XPOS : 0.0620265
IPM1H04B.YPOS : -0.0207398
Waterfall Step Motor Position : 1.33478e+06
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.113033
Waterfall Tachometer : 2.21744
Waterfall Encoder : 1.26708
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868799
HacR_HPE1313A:0_Ch58 : -0.478027
HacR_HPE1313A:0_Ch55 : 23.877
HacR_HPE1313A:0_Ch54 : -0.785156
HacR_alignROLL : -0.302679
HacR_alignPITCH : -0.0742645
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.202148
HacL_HPE1313A:0_Ch55 : 25.5371
HacL_HPE1313A:0_Ch54 : 0.0922852
HacL_alignROLL : 0.278157
HacL_alignPITCH : 0.114605
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.86875
OTR x-position : -0.784698
OTR y-position : -1.3988
OTR x-width : 2.30319
OTR y-width : 1.80704
OTR data valid flag : No
Waterfall Step Motor Position : 1.33478e+06
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.11677
Waterfall Tachometer : 1.73404
Waterfall Encoder : 1.26727