    User name a-onl

    Log entry time 01:42:19 on October 28, 2001

    Entry number 75260

    keyword=Start_Run_1310,Run_type=production,beam_energy=4.627,beam_raster=on,comment_text=collimator open on both arms. Beo Target run. ps all 1.,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
    Beginning-of-run EPICS data for Run Number 1310 at Sun Oct 28 01:42:15 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.43
    Right Arm Q1 momentum : 1.06582
    Right Arm Q1 gauss meter : 0.020218
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.794
    Right Arm Q2 momentum : 1.06605
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.377
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.138
    Right Arm Q3 momentum : 1.06592
    Right Arm Q3 gauss meter : -0.1904
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.58
    Left Arm Q1 momentum : 4.12129
    Left Arm Q1 gauss meter : -0.26192
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.55
    Left Arm Q2 momentum : 4.12112
    Left Arm Q2 gauss meter : 0.9339
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.04
    Left Arm D1 momentum : 4.121
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.67
    Left Arm Q3 momentum : 4.12105
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0813495
    Current on Unser monitor : 5.18847
    Current on Upstream bcm : 0.0743948
    Current on Downstream bcm : 0.0883042
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 34.0449
    Tiefenbach Hall A energy : 4617.93
    Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    Arc1 dp/p : 8.91249e-05
    Arc2 dp/p : -0.000850043
    Waterfall Step Motor Position : 1.33478e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0980865
    Waterfall Tachometer : -0.682994
    Waterfall Encoder : 1.26845
    Right Arm Arm Collimator : 0.86543
    Left Arm Arm Collimator : 0.86875
    HacR_HPE1313A:0_Ch58 : -0.477539
    HacR_HPE1313A:0_Ch55 : 23.877
    HacR_HPE1313A:0_Ch54 : -0.786133
    HacR_alignROLL : -0.303172
    HacR_alignPITCH : -0.0742645
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202637
    HacL_HPE1313A:0_Ch55 : 25.6348
    HacL_HPE1313A:0_Ch54 : 0.0898438
    HacL_alignROLL : 0.276761
    HacL_alignPITCH : 0.11373
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 60
    Right Arm Angle Vernier : -39.4
    Right Arm Scattering Angle : 59.9699
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4999
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1