keyword=DAQ problems, fixed
The DAQ stopped working at approx 05:30 and I was
called in. The symptom was that anything on 192 subnet
could not be pinged. E.g. you could not ping adaqs2 from
adaql2 (but you could ping adaqs2-ep, which is the 164
interface on the same computer). Solution was to go into
the hall and cycle the power on the 192 network switch.