• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:52:53 on November 1, 2001

    Entry number 75570

    keyword=End_of_Run_1423
    ****************************
     Run Number: 1423
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=CW 100uA,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=74.82,target_name=H2O,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=114   ps2=16   ps3=2400   ps4=240   ps5=1   ps8=65535   
    
    EVENTS[0]: 1498723      [+]: 736989       [-]: 733894       
    TIME  [0]: 59.416 mins  [+]: 29.160 mins  [-]: 29.157 mins  
    LIVE  [0]:  95.13%      [+]:  95.03%      [-]:  95.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :69.1/7873.4 Hz   T2[0] :35.7/571.2 Hz   T3[0] :81.6/195930.2 Hz   T4[0] :46.3/11120.2 Hz   T5[0] :209.2/209.2 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :69.2/7885.6 Hz   T2[+] :35.8/572.3 Hz   T3[+] :81.8/196236.4 Hz   T4[+] :46.4/11137.8 Hz   T5[+] :210.1/210.1 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :69.0/7860.8 Hz   T2[-] :35.6/570.2 Hz   T3[-] :81.5/195613.4 Hz   T4[-] :46.3/11101.6 Hz   T5[-] :208.2/208.2 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 246213/28068383  T2[0] : 127271/2036339  T3[0] : 291033/698481265  T4[0] : 165178/39642789  T5[0] : 745639/745639   T8[0] :     55/3650509  
    T1[+] : 121022/13796593  T2[+] :  62582/1001321  T3[+] : 143055/343332136  T4[+] :  81193/19486429  T5[+] : 367670/367670   T8[+] :     27/1791574  
    T1[-] : 120631/13752017  T2[-] :  62345/997531   T3[-] : 142589/342213843  T4[-] :  80922/19421510  T5[-] : 364274/364274   T8[-] :     27/1791426  
    
    AVERAGE CURRENT
    BCM x1 : 80.8828uA  BCM x3 : 81.0830uA  BCM x10: -29.1644uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1435 ppm     BCM u3 :     1395 ppm     BCM u10:    580.9 ppm     
    BCM d1 :     1435 ppm     BCM d3 :     1365 ppm     BCM d10:      686 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.285          BCM u3 [0]:0.2865         BCM u10[0]:-0.1116        
    BCM u1 [+]:0.1401         BCM u3 [+]:0.1408         BCM u10[+]:0.1137         
    BCM u1 [-]:0.1397         BCM u3 [-]:0.1404         BCM u10[-]:0.1136         
    
    BCM d1 [0]:0.2917         BCM d3 [0]:0.2917         BCM d10[0]:-0.09634       
    BCM d1 [+]:0.1434         BCM d3 [+]:0.1433         BCM d10[+]:0.1184         
    BCM d1 [-]:0.1429         BCM d3 [-]:0.1429         BCM d10[-]:0.1182         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1423 at Thu Nov 1 14:52:45 EST 2001
    Right Arm D1 momentum : 1.06608
    Right Arm arm angle : 74.8198
    Left Arm D1 momentum : 4.12098
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 4617.06
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.605
    Right Arm Q1 momentum : 1.06606
    Right Arm Q1 gauss meter : 0.020181
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.954
    Right Arm Q2 momentum : 1.06642
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.869
    Right Arm D1 momentum : 1.06608
    Right Arm D1 NMR : 0.39561
    Right Arm Q3 power supply current : 424.103
    Right Arm Q3 momentum : 1.06583
    Right Arm Q3 gauss meter : -0.19038
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.48
    Left Arm Q1 momentum : 4.12116
    Left Arm Q1 gauss meter : -0.26179
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.41
    Left Arm Q2 momentum : 4.12135
    Left Arm Q2 gauss meter : 0.9337
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.43
    Left Arm D1 momentum : 4.12098
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.63
    Left Arm Q3 momentum : 4.12096
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 100.078
    Current on Unser monitor : 106.061
    Current on Upstream bcm : 99.3847
    Current on Downstream bcm : 100.77
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 99.5822
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.06
    Tiefenbach Hall C energy : 3479.09
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.807233
    IPM1H04A.XPOS : -0.0728307
    IPM1H04A.YPOS : -0.0345022
    IPM1H04B.XPOS : 0.0158483
    IPM1H04B.YPOS : -0.0402334
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.32795
    Waterfall Tachometer : 1266.81
    Waterfall Encoder : 1.80258
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.86875
    HacR_HPE1313A:0_Ch58 : -0.491699
    HacR_HPE1313A:0_Ch55 : 23.9746
    HacR_HPE1313A:0_Ch54 : -0.737793
    HacR_alignROLL : -0.253546
    HacR_alignPITCH : -0.0624752
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.20166
    HacL_HPE1313A:0_Ch55 : 25.8301
    HacL_HPE1313A:0_Ch54 : 0.09375
    HacL_alignROLL : 0.280799
    HacL_alignPITCH : 0.115335
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868701
    OTR x-position : -0.847447
    OTR y-position : -3.60544
    OTR x-width : 0.391483
    OTR y-width : 0.243188
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.4195
    Waterfall Tachometer : 1257.14
    Waterfall Encoder : 1.80229