    User name a-onl

    Log entry time 14:11:24 on November 2, 2001

    Entry number 75640

    keyword=Start_Run_1453,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=withrich test with beo during ep,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=71.12,target_name=beo,target_type=BeO
    Beginning-of-run EPICS data for Run Number 1453 at Fri Nov 2 14:11:19 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=32000,ps2=32000,ps3=20,ps4=240,ps5=1,ps8=65535
    
    
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter : 0.020172
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.645
    Right Arm Q2 momentum : 1.06571
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.869
    Right Arm D1 momentum : 1.06608
    Right Arm D1 NMR : 0.39561
    Right Arm Q3 power supply current : 424.085
    Right Arm Q3 momentum : 1.06578
    Right Arm Q3 gauss meter : -0.19039
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.48
    Left Arm Q1 momentum : 4.12116
    Left Arm Q1 gauss meter : -0.26179
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.45
    Left Arm Q2 momentum : 4.12089
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.43
    Left Arm D1 momentum : 4.12096
    Left Arm D1 NMR : 1.52679
    Left Arm Q3 power supply current : 1640.64
    Left Arm Q3 momentum : 4.12099
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0599452
    Current on Unser monitor : 6.97651
    Current on Upstream bcm : 0.0594202
    Current on Downstream bcm : 0.0604702
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 4617.92
    Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    Arc1 dp/p : 6.08185e-05
    Arc2 dp/p : -0.00101948
    Waterfall Step Motor Position : 1.33478e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.111165
    Waterfall Tachometer : 1.00893
    Waterfall Encoder : 1.25953
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.86875
    HacR_HPE1313A:0_Ch58 : -0.493164
    HacR_HPE1313A:0_Ch55 : 24.1211
    HacR_HPE1313A:0_Ch54 : -0.723633
    HacR_alignROLL : -0.239673
    HacR_alignPITCH : -0.0607459
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202637
    HacL_HPE1313A:0_Ch55 : 25.8789
    HacL_HPE1313A:0_Ch54 : 0.0942383
    HacL_alignROLL : 0.280957
    HacL_alignPITCH : 0.114608
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 70.5
    Right Arm Angle Vernier : 73.4
    Right Arm Scattering Angle : 71.1201
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4998
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1