• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:49:20 on November 2, 2001

    Entry number 75647

    keyword=End_of_Run_1456
    ****************************
     Run Number: 1456
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=kinematics f+,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=71.12,target_name=H2O,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=114   ps2=16   ps3=2400   ps4=240   ps5=1   ps8=65535   
    
    EVENTS[0]: 79353        [+]: 38971        [-]: 38888        
    TIME  [0]: 2.918 mins  [+]: 1.431 mins  [-]: 1.431 mins  
    LIVE  [0]:  94.10%      [+]:  94.04%      [-]:  94.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :83.4/9509.4 Hz   T2[0] :33.9/542.7 Hz   T3[0] :72.3/173547.7 Hz   T4[0] :40.8/9793.4 Hz   T5[0] :251.2/251.2 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :83.7/9539.4 Hz   T2[+] :34.0/544.8 Hz   T3[+] :72.5/174024.1 Hz   T4[+] :40.9/9826.2 Hz   T5[+] :251.4/251.4 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :83.2/9483.5 Hz   T2[-] :33.8/541.5 Hz   T3[-] :72.1/173142.1 Hz   T4[-] :40.7/9768.0 Hz   T5[-] :251.0/251.0 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14603/1664787  T2[0] :   5937/95002    T3[0] :  12659/30382549  T4[0] :   7143/1714506  T5[0] :  43980/43980    T8[0] :      2/179269   
    T1[+] :   7185/819201   T2[+] :   2924/46787    T3[+] :   6226/14944488  T4[+] :   3515/843834   T5[+] :  21591/21591    T8[+] :      1/87937    
    T1[-] :   7143/814389   T2[-] :   2906/46498    T3[-] :   6195/14868411  T4[-] :   3495/838819   T5[-] :  21551/21551    T8[-] :      1/87935    
    
    AVERAGE CURRENT
    BCM x1 : 73.0913uA  BCM x3 : 73.2798uA  BCM x10: 60.8049uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1990 ppm     BCM u3 :     1931 ppm     BCM u10:    987.7 ppm     
    BCM d1 :     1994 ppm     BCM d3 :     1889 ppm     BCM d10:     1099 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01265        BCM u3 [0]:0.01272        BCM u10[0]:0.01044        
    BCM u1 [+]:0.006219       BCM u3 [+]:0.006251       BCM u10[+]:0.005129       
    BCM u1 [-]:0.006194       BCM u3 [-]:0.006227       BCM u10[-]:0.005119       
    
    BCM d1 [0]:0.01294        BCM d3 [0]:0.01294        BCM d10[0]:0.01085        
    BCM d1 [+]:0.006362       BCM d3 [+]:0.006362       BCM d10[+]:0.005327       
    BCM d1 [-]:0.006337       BCM d3 [-]:0.006338       BCM d10[-]:0.005315       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1456 at Fri Nov 2 15:49:15 EST 2001
    Right Arm D1 momentum : 1.06608
    Right Arm arm angle : 71.1201
    Left Arm D1 momentum : 4.12096
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 4617.94
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.71
    Right Arm Q1 momentum : 1.0662
    Right Arm Q1 gauss meter : 0.020188
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.934
    Right Arm Q2 momentum : 1.06638
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.87
    Right Arm D1 momentum : 1.06608
    Right Arm D1 NMR : 0.39561
    Right Arm Q3 power supply current : 424.337
    Right Arm Q3 momentum : 1.06642
    Right Arm Q3 gauss meter : -0.19041
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.37
    Left Arm Q1 momentum : 4.12102
    Left Arm Q1 gauss meter : -0.26177
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.5
    Left Arm Q2 momentum : 4.121
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.43
    Left Arm D1 momentum : 4.12096
    Left Arm D1 NMR : 1.52679
    Left Arm Q3 power supply current : 1640.62
    Left Arm Q3 momentum : 4.12093
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 98.5638
    Current on Unser monitor : 105.255
    Current on Upstream bcm : 97.9198
    Current on Downstream bcm : 99.2078
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 98.4537
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.94
    Tiefenbach Hall C energy : 3479.87
    Delta(E)/E width (MV_AI_DXWID) : 0.317613
    IPM1C12.XPOS : 0.0130627
    IPM1H04A.XPOS : -0.199186
    IPM1H04A.YPOS : -0.031873
    IPM1H04B.XPOS : -0.0423856
    IPM1H04B.YPOS : -0.0381737
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.05518
    Waterfall Tachometer : 1249.4
    Waterfall Encoder : 1.80003
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868848
    HacR_HPE1313A:0_Ch58 : -0.492676
    HacR_HPE1313A:0_Ch55 : 24.0723
    HacR_HPE1313A:0_Ch54 : -0.722168
    HacR_alignROLL : -0.238686
    HacR_alignPITCH : -0.0611951
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202148
    HacL_HPE1313A:0_Ch55 : 25.9277
    HacL_HPE1313A:0_Ch54 : 0.09375
    HacL_alignROLL : 0.279947
    HacL_alignPITCH : 0.114534
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.86875
    OTR x-position : -1.06087
    OTR y-position : -3.39506
    OTR x-width : 0.117164
    OTR y-width : 0.175529
    OTR data valid flag : Yes
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.06639
    Waterfall Tachometer : 1252.3
    Waterfall Encoder : 1.80131