Main INDEX
Monthly INDEX
PREV
NEXT
User name Kelly
Log entry time 15:58:43 on November 3,2001
Entry number 75735
keyword=day shift summary
0815: after smooth owl shift, beam has become unstable since about 0800
0900: beam stable 0830-0900, unstable 0900-0915
0930: IOC reading have increased approximately 10%, apparently after a trip and have remained constant since.
1030: CODA hung in run 1481. Run end failed. Required several attempts to restart CODA. Runs 1482-1483 junk.
1100: trigger efficiency
1115: IOC readings still 10% higher than during the night, no further change since the step increasing earlier this morning.
1150: Simon and Larry decide that it is time to end F+
1230: have finally moved to E+. The lack of visible angle marks made it necessary to go back and forth a couple of times to be sure we had the right line.
1405: ROC14 lost. Reset easily this time.
1440: beam off to investigate fire alarm in south linac.
1447: beam back, apparently false alarm
1451: beam off again, decided fire alarm is real
1600: still off. The South Linac returned to beam permit, but then was taken to controlled access again a few minutes ago.
============================================
F+ kinematics
run Q(uA-hr)
1478 64
1479 64
1480 63
1481 57 CODA hung
1482 junk
1483 junk
1484 trigger efficiency check
1485 63 end of F+ with 1970 uA-hr total
============================================
E+ kinematics
run Q(uA-hr) comment
1486 47
1487 51 adjusted PS
1488 37 CODA hung, run end failed, estimate Q from # events
1489 50
1490 junk
1491 trigger efficiency with 245k, then off for fire alarm