    User name Kelly

    Log entry time 16:13:13 on November 4,2001

    Entry number 75819

    keyword=day shift summary

    0840: waiting for beam. MCC says that injector experts are working on
    "steering issues" and that it might take another half hour.
    0945: beam back. Resume C+
    1142: end C+
    1215: start B+
    1430: end B+
    1450: start q-pointing
    1514: the target problem is back.
    1536: We ended run 1522 and tried unsuccessfully to contact Meekins.
    1540: trip due to ionization chamber near dump. Shut off pump and waited a few minutes (per suggestion of Folts).
    1607: Restart pump and take beam. The water level at the return is higher now than before. The position encoder is at 1.7935; we have not adjusted position.
    Ionization readings now back to 850/350, apparently normal. Seems the problem is related to water level, not position encoder.

    C+ kinematics
    run Q(uA-hr) comment
    1507 31
    1508 31
    1509 30
    1510 31
    1511 31 stop with 240 uA-hr
    1512 trigger efficiency
    =======================================
    B+ kinematics
    run Q(uA-hr) comment
    1513 26
    1514 27
    1515 26
    1516 27
    1517 27
    1518 27
    1519 28
    1520 28 stop with 216 uA-hr
    1521 trigger efficiency
    ======================================
    q-pointing
    run Q(uA-hr) comment
    1522
    1523 another sieve run after restarting target pump