NEXT
User name a-onl
Log entry time 19:34:06 on November 10, 2001
Entry number 76881
keyword=End_of_Run_2007
****************************
Run Number: 2007
End of Run Comment:
Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=G- KINEMATICS. Current 75uA.,2000/100/2200/248/1/ ps settings,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=37.616,target_name=H2O,target_type=Waterfall
PRESCALE FACTORS:ps1=2000 ps2=100 ps3=2200 ps4=248 ps5=1 ps8=65535
EVENTS[0]: 1354826 [+]: 663661 [-]: 665672
TIME [0]: 12.648 mins [+]: 6.206 mins [-]: 6.205 mins
LIVE [0]: 81.24% [+]: 81.10% [-]: 81.25%
TRIGGER RATES: PRES/REAL
T1[0] :95.4/190879.0 Hz T2[0] :42.7/4273.2 Hz T3[0] :83.7/184227.1 Hz T4[0] :41.5/10299.3 Hz T5[0] :1934.2/1934.2 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :95.3/190666.2 Hz T2[+] :42.7/4267.9 Hz T3[+] :83.6/184007.6 Hz T4[+] :41.5/10288.3 Hz T5[+] :1934.7/1934.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :95.6/191124.5 Hz T2[-] :42.8/4279.3 Hz T3[-] :83.8/184467.6 Hz T4[-] :41.6/10312.2 Hz T5[-] :1937.0/1937.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 72429/144858883 T2[0] : 32429/3242923 T3[0] : 63550/139810717 T4[0] : 31516/7816156 T5[0] :1467840/1467840 T8[0] : 11/777118
T1[+] : 35496/70992639 T2[+] : 15891/1589104 T3[+] : 31142/68513344 T4[+] : 15446/3830760 T5[+] : 720359/720359 T8[+] : 5/381276
T1[-] : 35575/71151123 T2[-] : 15930/1593099 T3[-] : 31214/68672920 T4[-] : 15479/3838983 T5[-] : 721100/721100 T8[-] : 5/381211
AVERAGE CURRENT
BCM x1 : 75.4800uA BCM x3 : 75.6816uA BCM x10: 70.3746uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1179 ppm BCM u3 : -1156 ppm BCM u10: -764.5 ppm
BCM d1 : -1180 ppm BCM d3 : -1135 ppm BCM d10: -816.3 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.05663 BCM u3 [0]:0.05693 BCM u10[0]:0.05275
BCM u1 [+]:0.02775 BCM u3 [+]:0.0279 BCM u10[+]:0.02586
BCM u1 [-]:0.02782 BCM u3 [-]:0.02796 BCM u10[-]:0.0259
BCM d1 [0]:0.05793 BCM d3 [0]:0.05794 BCM d10[0]:0.05406
BCM d1 [+]:0.02839 BCM d3 [+]:0.0284 BCM d10[+]:0.02651
BCM d1 [-]:0.02845 BCM d3 [-]:0.02846 BCM d10[-]:0.02654
****************************
End-of-run EPICS data for Run Number 2007 at Sat Nov 10 19:20:10 EST 2001
Right Arm D1 momentum : 1.066
Right Arm arm angle : 37.6163
Left Arm D1 momentum : 4.12099
Left Arm arm angle : 12.5003
Tiefenbach Hall A energy :
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current : 801.57
Right Arm Q1 momentum : 1.06601
Right Arm Q1 gauss meter : 0.020178
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.738
Right Arm Q2 momentum : 1.06592
Right Arm Q2 gauss meter : -0.2417
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.817
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current : 424.217
Right Arm Q3 momentum : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 1.06596
Right Arm Q3 gauss meter : -0.19041
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3100.37
Left Arm Q1 momentum : 4.12102
Left Arm Q1 gauss meter : -0.26173
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.51
Left Arm Q2 momentum : 4.12101
Left Arm Q2 gauss meter : 0.9336
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1567.68
Left Arm D1 momentum : 4.121
Left Arm D1 NMR : 1.5268
Left Arm Q3 power supply current : 1640.72
Left Arm Q3 momentum : 4.12143
Left Arm Q3 gauss meter : -0.8206
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 74.6056
Current on Unser monitor : 80.8635
Current on Upstream bcm : 74.6799
Current on Downstream bcm : 75.3875
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 74.9932
MBSY1c Hall A Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.29
Tiefenbach Hall A energy : 4617.92
Tiefenbach Hall C energy : 3479.43
Delta(E)/E width (MV_AI_DXWID) : 0.959298
IPM1C12.XPOS : 0.00215626
IPM1H04A.XPOS : -0.223696
IPM1H04A.YPOS : -0.0461023
IPM1H04B.XPOS : -0.0227209
IPM1H04B.YPOS : 0.0256974
Waterfall Step Motor Position : 7.67501e+06
Waterfall Pump Speed : 3589
Waterfall Flow Meter : 4.35037
Waterfall Tachometer : 1257.38
Waterfall Encoder : 1.78033
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.868799
HacR_HPE1313A:0_Ch58 : -0.511719
HacR_HPE1313A:0_Ch55 : 24.2676
HacR_HPE1313A:0_Ch54 : -0.901367
HacR_alignROLL : -0.419458
HacR_alignPITCH : -0.0444605
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.209473
HacL_HPE1313A:0_Ch55 : 25.9277
HacL_HPE1313A:0_Ch54 : 0.0668945
HacL_alignROLL : 0.254205
HacL_alignPITCH : 0.108708
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.868799
OTR x-position : 0.0298238
OTR y-position : -0.132251
OTR x-width : 0.146827
OTR y-width : 0.344367
OTR data valid flag : Yes
Waterfall Step Motor Position : 7.67501e+06
Waterfall Pump Speed : 3589
Waterfall Flow Meter : 4.35224
Waterfall Tachometer : 1285.42
Waterfall Encoder : 1.78072