• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 13:59:27 on November 15, 2001

    Entry number 77258

    keyword=Start_Run_2175,Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=Production running, Kinematics I+,ps=42/11/2380/276/1, with ROC14,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=84.17,target_name=H2O,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 2175 at Thu Nov 15 13:59:22 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=42,ps2=11,ps3=2380,ps4=276,ps5=1,ps8=65535
    
    Right Arm Q1 power supply current : 801.57
    Right Arm Q1 momentum : 1.06601
    Right Arm Q1 gauss meter : 0.020183
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.648
    Right Arm Q2 momentum : 1.06571
    Right Arm Q2 gauss meter : -0.24123
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 365.99
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.159
    Right Arm Q3 momentum : 1.06597
    Right Arm Q3 gauss meter : -0.18991
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.26172
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.62
    Left Arm Q2 momentum : 4.12127
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.57
    Left Arm D1 momentum : 4.121
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.58
    Left Arm Q3 momentum : 4.12083
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 94.8616
    Current on Unser monitor : 101.735
    Current on Upstream bcm : 94.1789
    Current on Downstream bcm : 95.5443
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 94.6318
    Tiefenbach Hall A energy : 4617.9
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : 8.37125e-05
    Arc2 dp/p : -0.00108527
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3589
    Waterfall Flow Meter : 4.41203
    Waterfall Tachometer : 1259.07
    Waterfall Encoder : 1.76023
    Right Arm Arm Collimator : 0.865576
    Left Arm Arm Collimator : 0.868848
    HacR_HPE1313A:0_Ch58 : -0.487305
    HacR_HPE1313A:0_Ch55 : 24.1699
    HacR_HPE1313A:0_Ch54 : -0.695801
    HacR_alignROLL : -0.212911
    HacR_alignPITCH : -0.0667207
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.205078
    HacL_HPE1313A:0_Ch55 : 25.9766
    HacL_HPE1313A:0_Ch54 : 0.0878906
    HacL_alignROLL : 0.27561
    HacL_alignPITCH : 0.112205
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 84
    Right Arm Angle Vernier : -4.7
    Right Arm Scattering Angle : 84.1699
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4999
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1