    User name a-onl

    Log entry time 14:11:20 on December 7, 2001

    Entry number 78947

    keyword=Start_Run_2935,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=rich tests, HV scan,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=0.916,rightarm_theta=37.62,target_name=BeO,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 2935 at Fri Dec 7 14:11:14 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; 
    ps1=65535,ps2=65535,ps3=4,ps4=65535,ps5=65535,ps8=65535
    
     
    Right Arm Q1 power supply current : 688.87
    Right Arm Q1 momentum : 0.91613
    Right Arm Q1 gauss meter : 0.017402
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 394.05
    Right Arm Q2 momentum : 0.915612
    Right Arm Q2 gauss meter : -0.208
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 313.554
    Right Arm D1 momentum : 0.916001
    Right Arm D1 NMR : 0.339917
    Right Arm Q3 power supply current : 364.286
    Right Arm Q3 momentum : 0.915501
    Right Arm Q3 gauss meter : -0.16369
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.26183
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.4
    Left Arm Q2 momentum : 4.12077
    Left Arm Q2 gauss meter : 0.9337
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.3
    Left Arm D1 momentum : 4.12093
    Left Arm D1 NMR : 1.52678
    Left Arm Q3 power supply current : 1640.75
    Left Arm Q3 momentum : 4.12125
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 5.12898
    Current on Unser monitor : 11.5951
    Current on Upstream bcm : 5.13485
    Current on Downstream bcm : 5.1231
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 5.15053
    Tiefenbach Hall A energy : 4617.89
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : 4.03514e-05
    Arc2 dp/p : -0.00144328
    Waterfall Step Motor Position : 1.33478e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.129848
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.1467
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.536621
    HacR_HPE1313A:0_Ch55 : 21.6797
    HacR_HPE1313A:0_Ch54 : -0.931641
    HacR_alignROLL : -0.453579
    HacR_alignPITCH : -0.0169943
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.224121
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : 0.0708008
    HacL_alignROLL : 0.254623
    HacL_alignPITCH : 0.0915832
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 37.5
    Right Arm Angle Vernier : -13.5
    Right Arm Scattering Angle : 37.6192
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.5003
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1