Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 05:36:50 on December 8, 2001
Entry number 79036
keyword=End_of_Run_2975
****************************
Run Number: 2975
End of Run Comment:
Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=Trigger efficiency run,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=0.991,rightarm_theta=37.62,target_name=water,target_type=Waterfall
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=65535
EVENTS[0]: 2621572 [+]: 1288972 [-]: 1284809
TIME [0]: 7.982 mins [+]: 3.917 mins [-]: 3.919 mins
LIVE [0]: 1.33% [+]: 1.33% [-]: 1.33%
TRIGGER RATES: PRES/REAL
T1[0] :222703.5/222703.5 Hz T2[0] :4558.4/4558.4 Hz T3[0] :172754.4/172754.4 Hz T4[0] :9402.9/9402.9 Hz T5[0] :2128.7/2128.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :223332.6/223332.6 Hz T2[+] :4567.1/4567.1 Hz T3[+] :173295.8/173295.8 Hz T4[+] :9433.9/9433.9 Hz T5[+] :2150.2/2150.2 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :222060.5/222060.5 Hz T2[-] :4549.0/4549.0 Hz T3[-] :172201.4/172201.4 Hz T4[-] :9369.6/9369.6 Hz T5[-] :2110.7/2110.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :106663232/106663232 T2[0] :2183248/2183248 T3[0] :82740254/82740254 T4[0] :4503478/4503478 T5[0] :1019546/1019546 T8[0] : 7/490442
T1[+] :52493406/52493406 T2[+] :1073482/1073482 T3[+] :40732473/40732473 T4[+] :2217394/2217394 T5[+] : 505402/505402 T8[+] : 3/240687
T1[-] :52211759/52211759 T2[-] :1069574/1069574 T3[-] :40488685/40488685 T4[-] :2203029/2203029 T5[-] : 496269/496269 T8[-] : 3/240767
AVERAGE CURRENT
BCM x1 : 75.2851uA BCM x3 : 75.4739uA BCM x10: 64.6226uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 3374 ppm BCM u3 : 3298 ppm BCM u10: 2265 ppm
BCM d1 : 3371 ppm BCM d3 : 3230 ppm BCM d10: 797.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.03515 BCM u3 [0]:0.03534 BCM u10[0]:0.03294
BCM u1 [+]:0.01731 BCM u3 [+]:0.0174 BCM u10[+]:0.0162
BCM u1 [-]:0.0172 BCM u3 [-]:0.01729 BCM u10[-]:0.01614
BCM d1 [0]:0.03696 BCM d3 [0]:0.03696 BCM d10[0]:0.02896
BCM d1 [+]:0.0182 BCM d3 [+]:0.01819 BCM d10[+]:0.01422
BCM d1 [-]:0.01808 BCM d3 [-]:0.01808 BCM d10[-]:0.0142
****************************
End-of-run EPICS data for Run Number 2975 at Sat Dec 8 05:36:42 EST 2001
Right Arm D1 momentum : 0.991
Right Arm arm angle : 37.6192
Left Arm D1 momentum : 4.12093
Left Arm arm angle : 12.5002
Tiefenbach Hall A energy : 4617.9
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Top VDC Current : -13.2812
Right Arm Bottom VDC Current : -11.5723
Left Arm Top VDC Current : -13.9648
Left Arm Bottom VDC Current : -11.8164
Right Arm Q1 power supply current : 745.22
Right Arm Q1 momentum : 0.99107
Right Arm Q1 gauss meter : 0.018789
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 426.459
Right Arm Q2 momentum : 0.990918
Right Arm Q2 gauss meter : -0.2251
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 340.146
Right Arm D1 momentum : 0.991
Right Arm D1 NMR : 0.367748
Right Arm Q3 power supply current : 394.183
Right Arm Q3 momentum : 0.990637
Right Arm Q3 gauss meter : -0.17704
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3100.48
Left Arm Q1 momentum : 4.12116
Left Arm Q1 gauss meter : -0.26178
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.54
Left Arm Q2 momentum : 4.12128
Left Arm Q2 gauss meter : 0.9337
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1567.28
Left Arm D1 momentum : 4.12093
Left Arm D1 NMR : 1.52678
Left Arm Q3 power supply current : 1640.7
Left Arm Q3 momentum : 4.12113
Left Arm Q3 gauss meter : -0.8207
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 74.1771
Current on Unser monitor : 80.5341
Current on Upstream bcm : 73.7125
Current on Downstream bcm : 74.6416
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 74.8345
MBSY1c Hall A Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.29
Tiefenbach Hall A energy : 4617.9
Tiefenbach Hall C energy : 3480.42
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00540987
IPM1H04A.XPOS : 0.451422
IPM1H04A.YPOS : 0.0365764
IPM1H04B.XPOS : -0.0281302
IPM1H04B.YPOS : 0.0943095
Waterfall Step Motor Position : 7.67501e+06
Waterfall Pump Speed : 3566
Waterfall Flow Meter : 3.95429
Waterfall Tachometer : 1284.45
Waterfall Encoder : 1.70466
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868506
HacR_HPE1313A:0_Ch58 : -0.533203
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.932129
HacR_alignROLL : -0.453247
HacR_alignPITCH : -0.0209829
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.221191
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : 0.0727539
HacL_alignROLL : 0.257417
HacL_alignPITCH : 0.0947134
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868506
OTR x-position : 0.246836
OTR y-position : 1.33234
OTR x-width : 0.129659
OTR y-width : 0.113801
OTR data valid flag : Yes
Waterfall Step Motor Position : 7.67501e+06
Waterfall Pump Speed : 3566
Waterfall Flow Meter : 3.98231
Waterfall Tachometer : 1224.27
Waterfall Encoder : 1.70475