• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:05:17 on December 8, 2001

    Entry number 79115

    keyword=End_of_Run_3012
    ****************************
     Run Number: 3012
     End of Run Comment:
    Run_type=optics,beam_energy=4.620,beam_raster=off,comment_text=q kinematics, coll open,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.22,target_name=water,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=380   ps2=22   ps3=1740   ps4=190   ps5=1   ps8=65535   
    
    EVENTS[0]: 2705176      [+]: 1331823      [-]: 1323455      
    TIME  [0]: 22.329 mins  [+]: 10.959 mins  [-]: 10.961 mins  
    LIVE  [0]:  75.26%      [+]:  75.18%      [-]:  75.33%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :94.7/35972.6 Hz   T2[0] :48.2/1059.9 Hz   T3[0] :94.4/164341.1 Hz   T4[0] :47.7/9070.4 Hz   T5[0] :2398.1/2398.1 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :95.0/36083.0 Hz   T2[+] :48.3/1063.3 Hz   T3[+] :94.8/164871.8 Hz   T4[+] :47.9/9104.7 Hz   T5[+] :2408.3/2408.3 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :94.4/35853.6 Hz   T2[-] :48.0/1056.1 Hz   T3[-] :94.1/163788.0 Hz   T4[-] :47.6/9035.8 Hz   T5[-] :2387.4/2387.4 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 126824/48193411  T2[0] :  64545/1420005  T3[0] : 126535/220171788  T4[0] :  63957/12151903  T5[0] :3212789/3212789  T8[0] :     20/1371878  
    T1[+] :  62437/23726393  T2[+] :  31780/699164   T3[+] :  62305/108411429  T4[+] :  31509/5986806  T5[+] :1583560/1583560  T8[+] :     10/673331   
    T1[-] :  62048/23578604  T2[-] :  31568/694507   T3[-] :  61903/107712816  T4[-] :  31275/5942259  T5[-] :1570015/1570015  T8[-] :     10/673419   
    
    AVERAGE CURRENT
    BCM x1 : 71.7926uA  BCM x3 : 71.9749uA  BCM x10: 60.9596uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     3031 ppm     BCM u3 :     2963 ppm     BCM u10:     1990 ppm     
    BCM d1 :     3030 ppm     BCM d3 :     2901 ppm     BCM d10:    509.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.09387        BCM u3 [0]:0.09437        BCM u10[0]:0.08778        
    BCM u1 [+]:0.04621        BCM u3 [+]:0.04645        BCM u10[+]:0.04317        
    BCM u1 [-]:0.04594        BCM u3 [-]:0.04618        BCM u10[-]:0.043          
    
    BCM d1 [0]:0.09849        BCM d3 [0]:0.09848        BCM d10[0]:0.07556        
    BCM d1 [+]:0.04848        BCM d3 [+]:0.04848        BCM d10[+]:0.03711        
    BCM d1 [-]:0.0482         BCM d3 [-]:0.0482         BCM d10[-]:0.03707        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3012 at Sat Dec 8 21:05:04 EST 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2201
    Left Arm D1 momentum : 4.12092
    Left Arm arm angle : 12.5001
    Tiefenbach Hall A energy : 4617.9
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Top VDC Current : -1.41602
    Right Arm Bottom VDC Current : -2.63672
    Left Arm Top VDC Current : -14.502
    Left Arm Bottom VDC Current : -15.8203
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter : 0.020181
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.617
    Right Arm Q2 momentum : 1.06564
    Right Arm Q2 gauss meter : -0.2419
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.348
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.395579
    Right Arm Q3 power supply current : 424.144
    Right Arm Q3 momentum : 1.06593
    Right Arm Q3 gauss meter : -0.19046
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.58
    Left Arm Q1 momentum : 4.12129
    Left Arm Q1 gauss meter : -0.26177
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.52
    Left Arm Q2 momentum : 4.12104
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.3
    Left Arm D1 momentum : 4.12091
    Left Arm D1 NMR : 1.52677
    Left Arm Q3 power supply current : 1640.62
    Left Arm Q3 momentum : 4.12093
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 73.5611
    Current on Unser monitor : 80.7229
    Current on Upstream bcm : 73.113
    Current on Downstream bcm : 73.8615
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 74.4658
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    MBSY1c Bdl :
    MBSY3c Hall C Beam energy : 3489.69
    Tiefenbach Hall A energy : 4617.9
    Tiefenbach Hall C energy : 3479.21
    Delta(E)/E width (MV_AI_DXWID) : 0.170789
    IPM1C12.XPOS : -0.0017142
    IPM1H04A.XPOS : 0.431228
    IPM1H04A.YPOS : 0.0459107
    IPM1H04B.XPOS : -0.0452501
    IPM1H04B.YPOS : 0.102717
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.99913
    Waterfall Tachometer : 1274.3
    Waterfall Encoder : 1.70054
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868506
    HacR_HPE1313A:0_Ch58 : -0.525391
    HacR_HPE1313A:0_Ch55 : 21.6309
    HacR_HPE1313A:0_Ch54 : -0.832031
    HacR_alignROLL : -0.35257
    HacR_alignPITCH : -0.0277621
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.22168
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : 0.0839844
    HacL_alignROLL : 0.267249
    HacL_alignPITCH : 0.0939121
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868506
    OTR x-position : 0.209624
    OTR y-position : 1.32744
    OTR x-width : 0.145034
    OTR y-width : 0.13636
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 4.03649
    Waterfall Tachometer : 1262.46
    Waterfall Encoder : 1.70015