User name a-onl
Log entry time 22:53:52 on December 8, 2001
Entry number 79124
keyword=Start_Run_3016,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=junk run,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
Beginning-of-run EPICS data for Run Number 3016 at Sat Dec 8 22:53:46 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=38,ps2=3,ps3=272,ps4=27,ps5=1,ps8=65535
Right Arm Q1 power supply current : 801.605
Right Arm Q1 momentum : 1.06606
Right Arm Q1 gauss meter : 0.020176
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.584
Right Arm Q2 momentum : 1.06556
Right Arm Q2 gauss meter : -0.2419
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.357
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current : 424.169
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : -0.19041
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3100.51
Left Arm Q1 momentum : 4.1212
Left Arm Q1 gauss meter : -0.26179
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1774.77
Left Arm Q2 momentum : 4.12162
Left Arm Q2 gauss meter : 0.9336
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1567.31
Left Arm D1 momentum : 4.12091
Left Arm D1 NMR : 1.52677
Left Arm Q3 power supply current : 1640.67
Left Arm Q3 momentum : 4.12105
Left Arm Q3 gauss meter : -0.8207
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 29.1091
Current on Unser monitor : 37.0702
Current on Upstream bcm : 29.0308
Current on Downstream bcm : 29.1874
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 29.4851
Tiefenbach Hall A energy : 4617.89
Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
Arc1 dp/p : -4.07979e-05
Arc2 dp/p : -0.00147744
Waterfall Step Motor Position : 1.33478e+06
Waterfall Pump Speed : 3566
Waterfall Flow Meter : 3.90384
Waterfall Tachometer : 1315.15
Waterfall Encoder : 1.13543
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868555
HacR_HPE1313A:0_Ch58 : -0.503418
HacR_HPE1313A:0_Ch55 : 21.582
HacR_HPE1313A:0_Ch54 : -0.819336
HacR_alignROLL : -0.340252
HacR_alignPITCH : -0.0479516
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.220703
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : 0.0849609
HacL_alignROLL : 0.268178
HacL_alignPITCH : 0.0947853
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 60
Right Arm Angle Vernier : -39.5
Right Arm Scattering Angle : 59.9693
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.5
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1