    User name a-onl

    Log entry time 22:59:03 on December 8, 2001

    Entry number 79126

    keyword=Start_Run_3017,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=Target thickness calibration,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
    Beginning-of-run EPICS data for Run Number 3017 at Sat Dec 8 22:58:56 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; 
    ps1=38,ps2=3,ps3=272,ps4=27,ps5=1,ps8=65535
     
    Right Arm Q1 power supply current : 801.605
    Right Arm Q1 momentum : 1.06606
    Right Arm Q1 gauss meter : 0.020187
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.646
    Right Arm Q2 momentum : 1.06571
    Right Arm Q2 gauss meter : -0.2419
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.358
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 423.97
    Right Arm Q3 momentum : 1.0655
    Right Arm Q3 gauss meter : -0.1904
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.2618
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.48
    Left Arm Q2 momentum : 4.12095
    Left Arm Q2 gauss meter : 0.9335
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.3
    Left Arm D1 momentum : 4.12091
    Left Arm D1 NMR : 1.52677
    Left Arm Q3 power supply current : 1640.65
    Left Arm Q3 momentum : 4.121
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 29.0508
    Current on Unser monitor : 37.1688
    Current on Upstream bcm : 28.969
    Current on Downstream bcm : 29.1326
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.5564
    Tiefenbach Hall A energy : 4617.89
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : -5.47784e-05
    Arc2 dp/p : -0.00147822
    Waterfall Step Motor Position : 1.33478e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.90571
    Waterfall Tachometer : 1281.79
    Waterfall Encoder : 1.13543
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868506
    HacR_HPE1313A:0_Ch58 : -0.502441
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.820312
    HacR_alignROLL : -0.340252
    HacR_alignPITCH : -0.0484003
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.220703
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : 0.0854492
    HacL_alignROLL : 0.268643
    HacL_alignPITCH : 0.0947853
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 60
    Right Arm Angle Vernier : -39.5
    Right Arm Scattering Angle : 59.9693
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.5
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1