• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:53:19 on December 9, 2001

    Entry number 79158

    keyword=End_of_Run_3032
    ****************************
     Run Number: 3032
     End of Run Comment:
    Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=TRIGGER EFFICIENCY RUN,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=0.991,rightarm_theta=74.82,target_name=water,target_type=Waterfall
    TRIGGER EFFICIENCY RUN - coda crash
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 34174        [+]: 16372        [-]: 17160        
    TIME  [0]: 1.977 mins  [+]: 0.612 mins  [-]: 0.614 mins  
    LIVE  [0]:   0.11%      [+]:   0.18%      [-]:   0.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :15725.5/15725.5 Hz   T2[0] :778.9/778.9 Hz   T3[0] :225648.0/225648.0 Hz   T4[0] :12789.6/12789.6 Hz   T5[0] :234.8/234.8 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :15570.3/15570.3 Hz   T2[+] :768.4/768.4 Hz   T3[+] :223909.2/223909.2 Hz   T4[+] :12678.5/12678.5 Hz   T5[+] :230.4/230.4 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :15540.3/15540.3 Hz   T2[-] :764.5/764.5 Hz   T3[-] :222849.3/222849.3 Hz   T4[-] :12596.1/12596.1 Hz   T5[-] :229.1/229.1 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1865197/1865197  T2[0] :  92389/92389    T3[0] :26763968/26763968  T4[0] :1516961/1516961  T5[0] :  27855/27855    T8[0] :      1/121456   
    T1[+] : 572117/572117   T2[+] :  28234/28234    T3[+] :8227352/8227352  T4[+] : 465860/465860   T5[+] :   8467/8467     T8[+] :      0/37626    
    T1[-] : 572184/572184   T2[-] :  28148/28148    T3[-] :8205163/8205163  T4[-] : 463781/463781   T5[-] :   8436/8436     T8[-] :      0/37703    
    
    AVERAGE CURRENT
    BCM x1 : 98.8896uA  BCM x3 : 99.0810uA  BCM x10: 68.8205uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     3042 ppm     BCM u3 :     2982 ppm     BCM u10:     1318 ppm     
    BCM d1 :     3043 ppm     BCM d3 :     2908 ppm     BCM d10:    116.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01145        BCM u3 [0]:0.01151        BCM u10[0]:0.009336       
    BCM u1 [+]:0.003523       BCM u3 [+]:0.00354        BCM u10[+]:0.002883       
    BCM u1 [-]:0.003508       BCM u3 [-]:0.003527       BCM u10[-]:0.002882       
    
    BCM d1 [0]:0.012          BCM d3 [0]:0.01199        BCM d10[0]:0.00699        
    BCM d1 [+]:0.003691       BCM d3 [+]:0.003687       BCM d10[+]:0.002164       
    BCM d1 [-]:0.003676       BCM d3 [-]:0.003673       BCM d10[-]:0.002168       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3032 at Sun Dec 9 07:53:12 EST 2001
    Right Arm D1 momentum : 0.991
    Right Arm arm angle : 74.8209
    Left Arm D1 momentum : 4.12091
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.88
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Top VDC Current : 1.85547
    Right Arm Bottom VDC Current : 1.85547
    Left Arm Top VDC Current : -12.1582
    Left Arm Bottom VDC Current : -18.3594
    Right Arm Q1 power supply current : 745.22
    Right Arm Q1 momentum : 0.99107
    Right Arm Q1 gauss meter : 0.018787
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 426.286
    Right Arm Q2 momentum : 0.990516
    Right Arm Q2 gauss meter : -0.225
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 339.678
    Right Arm D1 momentum : 0.991
    Right Arm D1 NMR : 0.367748
    Right Arm Q3 power supply current : 394.286
    Right Arm Q3 momentum : 0.990895
    Right Arm Q3 gauss meter : -0.17714
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.26176
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.56
    Left Arm Q2 momentum : 4.12113
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.3
    Left Arm D1 momentum : 4.12091
    Left Arm D1 NMR : 1.52677
    Left Arm Q3 power supply current : 1640.52
    Left Arm Q3 momentum : 4.12067
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 49.3833
    Current on Unser monitor : 7.34227
    Current on Upstream bcm : 0.0634437
    Current on Downstream bcm : 98.7032
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.69
    Tiefenbach Hall A energy : 4617.88
    Tiefenbach Hall C energy : 3479.3
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.98418
    Waterfall Tachometer : 1273.82
    Waterfall Encoder : 1.69681
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.506836
    HacR_HPE1313A:0_Ch55 : 21.8262
    HacR_HPE1313A:0_Ch54 : -0.793945
    HacR_alignROLL : -0.314454
    HacR_alignPITCH : -0.0445638
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.21875
    HacL_HPE1313A:0_Ch55 : 23.4863
    HacL_HPE1313A:0_Ch54 : 0.090332
    HacL_alignROLL : 0.273369
    HacL_alignPITCH : 0.0970411
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868555
    OTR x-position : -7.9589
    OTR y-position : 7.73516
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.96176
    Waterfall Tachometer : 1269.22
    Waterfall Encoder : 1.69652