User name a-onl
Log entry time 21:57:16 on December 9, 2001
Entry number 79227
keyword=Start_Run_3066,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=RICH Test Pedestals_a7 ,daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
Beginning-of-run EPICS data for Run Number 3066 at Sun Dec 9 21:57:11 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=65535,ps4=65535,ps5=1,ps8=65535
Right Arm Q1 power supply current : 1729.49
Right Arm Q1 momentum : 2.30005
Right Arm Q1 gauss meter : -0.04307
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 989.717
Right Arm Q2 momentum : 2.2997
Right Arm Q2 gauss meter : 0.5199
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 806.679
Right Arm D1 momentum : 2.3
Right Arm D1 NMR : 0.853502
Right Arm Q3 power supply current : 915.37
Right Arm Q3 momentum : 2.30045
Right Arm Q3 gauss meter : 0.4106
Right Arm Q3 power supply polarity : disabled
Left Arm Q1 power supply current : 1557.36
Left Arm Q1 momentum : 2.07004
Left Arm Q1 gauss meter : 0.13222
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 891.083
Left Arm Q2 momentum : 2.0694
Left Arm Q2 gauss meter : -0.4697
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 704.305
Left Arm D1 momentum : 2.07001
Left Arm D1 NMR : 0.765958
Left Arm Q3 power supply current : 824.199
Left Arm Q3 momentum : 2.07023
Left Arm Q3 gauss meter : -0.4124
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0753678
Current on Unser monitor : 8.71832
Current on Upstream bcm : 0.0695738
Current on Downstream bcm : 0.0811619
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 4617.38
Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
Arc1 dp/p : -4.65298e-05
Arc2 dp/p : -0.00156857
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.101823
Waterfall Tachometer : -9.626
Waterfall Encoder : 0.958203
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868555
HacR_HPE1313A:0_Ch58 : -0.555176
HacR_HPE1313A:0_Ch55 : 21.6309
HacR_HPE1313A:0_Ch54 : -0.866211
HacR_alignROLL : -0.386075
HacR_alignPITCH : -0.00084269
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.200684
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0239258
HacL_alignROLL : 0.209159
HacL_alignPITCH : 0.113122
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -3.3
Right Arm Scattering Angle : 12.678
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.5011
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1