Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 22:40:58 on December 9, 2001
Entry number 79256
keyword=End_of_Run_3080
****************************
Run Number: 3080
End of Run Comment:
Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=RICH Test Pedestals_a21,daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
ped_a21.dat good run
PRESCALE FACTORS:ps1=65535 ps2=65535 ps3=65535 ps4=65535 ps5=1 ps8=65535
EVENTS[0]: 20590 [+]: 10115 [-]: 10106
TIME [0]: 1.757 mins [+]: 0.863 mins [-]: 0.863 mins
LIVE [0]: 99.99% [+]: 99.99% [-]: 100.00%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/202.2 Hz T2[0] : 0.0/13.3 Hz T3[0] : 0.0/202.8 Hz T4[0] : 0.0/11.7 Hz T5[0] :195.3/195.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/202.6 Hz T2[+] : 0.0/13.0 Hz T3[+] : 0.0/202.8 Hz T4[+] : 0.0/11.6 Hz T5[+] :195.4/195.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/201.8 Hz T2[-] : 0.0/13.6 Hz T3[-] : 0.0/202.6 Hz T4[-] : 0.0/12.1 Hz T5[-] :195.3/195.3 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/21317 T2[0] : 0/1397 T3[0] : 0/21374 T4[0] : 0/1237 T5[0] : 20591/20591 T8[0] : 1/107945
T1[+] : 0/10487 T2[+] : 0/672 T3[+] : 0/10499 T4[+] : 0/600 T5[+] : 10116/10116 T8[+] : 0/53001
T1[-] : 0/10446 T2[-] : 0/702 T3[-] : 0/10485 T4[-] : 0/626 T5[-] : 10106/10106 T8[-] : 0/53001
AVERAGE CURRENT
BCM x1 : 0.0118 uA BCM x3 : 0.0298 uA BCM x10: 0.0437 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 7955 ppm BCM u3 : 928.5 ppm BCM u10: 1186 ppm
BCM d1 :2.621E+05 ppm BCM d3 : 3377 ppm BCM d10: 749.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:2.328E-06 BCM u3 [0]:1.224E-06 BCM u10[0]:3.956E-06
BCM u1 [+]:1.116E-06 BCM u3 [+]:6.058E-07 BCM u10[+]:1.948E-06
BCM u1 [-]:1.099E-06 BCM u3 [-]:6.047E-07 BCM u10[-]:1.943E-06
BCM d1 [0]:1.512E-07 BCM d3 [0]:5.05E-06 BCM d10[0]:5.255E-06
BCM d1 [+]:7.777E-08 BCM d3 [+]:2.493E-06 BCM d10[+]:2.588E-06
BCM d1 [-]:4.547E-08 BCM d3 [-]:2.476E-06 BCM d10[-]:2.584E-06
****************************
End-of-run EPICS data for Run Number 3080 at Sun Dec 9 22:40:50 EST 2001
Right Arm D1 momentum : 2.3
Right Arm arm angle : 12.678
Left Arm D1 momentum : 2.07
Left Arm arm angle : 12.501
Tiefenbach Hall A energy : 4617.38
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Top VDC Current : 0.146484
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC Current : -0.683594
Left Arm Bottom VDC Current : 3.27148
Right Arm Q1 power supply current : 1729.49
Right Arm Q1 momentum : 2.30005
Right Arm Q1 gauss meter : -0.04307
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 989.819
Right Arm Q2 momentum : 2.29994
Right Arm Q2 gauss meter : 0.5199
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 806.688
Right Arm D1 momentum : 2.3
Right Arm D1 NMR : 0.853502
Right Arm Q3 power supply current : 915.132
Right Arm Q3 momentum : 2.29985
Right Arm Q3 gauss meter : 0.4105
Right Arm Q3 power supply polarity : disabled
Left Arm Q1 power supply current : 1557.29
Left Arm Q1 momentum : 2.06995
Left Arm Q1 gauss meter : 0.1322
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 891.323
Left Arm Q2 momentum : 2.06996
Left Arm Q2 gauss meter : -0.4697
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 704.285
Left Arm D1 momentum : 2.07
Left Arm D1 NMR : 0.765956
Left Arm Q3 power supply current : 824.201
Left Arm Q3 momentum : 2.07024
Left Arm Q3 gauss meter : -0.4125
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0765882
Current on Unser monitor : 8.87593
Current on Upstream bcm : 0.0710047
Current on Downstream bcm : 0.0816031
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
MBSY1c Bdl : 1.15476e+06
MBSY3c Hall C Beam energy : 3489.69
Tiefenbach Hall A energy : 4617.38
Tiefenbach Hall C energy : 3479.63
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0868766
Waterfall Tachometer : 3.18425
Waterfall Encoder : 0.957517
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868555
HacR_HPE1313A:0_Ch58 : -0.553223
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.864258
HacR_alignROLL : -0.384862
HacR_alignPITCH : -0.00245306
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.199707
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.0234375
HacL_alignROLL : 0.21001
HacL_alignPITCH : 0.113926
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868555
OTR x-position : -7.9589
OTR y-position : 7.73516
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0850083
Waterfall Tachometer : 4.15106
Waterfall Encoder : 0.95683