• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 00:49:56 on December 10, 2001

    Entry number 79279

    keyword=Start_Run_3093,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=dont use S0, but T3 and T5 are starting rich readout,old pedestal(4sig),daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
    Beginning-of-run EPICS data for Run Number 3093 at Mon Dec 10 00:49:51 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; 
    ps1=640,ps2=50,ps3=500,ps4=100,ps5=1,ps8=65535 
    Right Arm Q1 power supply current : 1729.49
    Right Arm Q1 momentum : 2.30005
    Right Arm Q1 gauss meter : -0.04305
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 989.975
    Right Arm Q2 momentum : 2.3003
    Right Arm Q2 gauss meter : 0.52
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 806.68
    Right Arm D1 momentum : 2.3
    Right Arm D1 NMR : 0.853502
    Right Arm Q3 power supply current : 914.988
    Right Arm Q3 momentum : 2.29949
    Right Arm Q3 gauss meter : 0.4105
    Right Arm Q3 power supply polarity : disabled
    Left Arm Q1 power supply current : 1557.26
    Left Arm Q1 momentum : 2.06991
    Left Arm Q1 gauss meter : 0.1322
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 891.089
    Left Arm Q2 momentum : 2.06941
    Left Arm Q2 gauss meter : -0.4697
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 704.287
    Left Arm D1 momentum : 2.07
    Left Arm D1 NMR : 0.765955
    Left Arm Q3 power supply current : 824.194
    Left Arm Q3 momentum : 2.07022
    Left Arm Q3 gauss meter : -0.4124
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 10.2955
    Current on Unser monitor : 19.1756
    Current on Upstream bcm : 10.2936
    Current on Downstream bcm : 10.2973
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 10.4424
    Tiefenbach Hall A energy : 4617.9
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : 2.51453e-05
    Arc2 dp/p : -0.00142137
    Waterfall Step Motor Position : 350016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.113033
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.04064
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868604
    HacR_HPE1313A:0_Ch58 : -0.553223
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.864258
    HacR_alignROLL : -0.384483
    HacR_alignPITCH : -0.00276953
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.200195
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : 0.0239258
    HacL_alignROLL : 0.210321
    HacL_alignPITCH : 0.113779
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -3.3
    Right Arm Scattering Angle : 12.678
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.501
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1