• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:23:30 on December 10, 2001

    Entry number 79298

    keyword=End_of_Run_3100
    ****************************
     Run Number: 3100
     End of Run Comment:
    Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=using S0, only T5s are starting rich readout,new pedestal(4sig),daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
     
    
    PRESCALE FACTORS:ps1=6400   ps2=40   ps3=960   ps4=100   ps5=1   ps8=65535   
    
    EVENTS[0]: 498752       [+]: 245636       [-]: 244229       
    TIME  [0]: 42.954 mins  [+]: 21.111 mins  [-]: 21.078 mins  
    LIVE  [0]:  80.97%      [+]:  80.91%      [-]:  81.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 4.9/31469.5 Hz   T2[0] :26.4/1055.6 Hz   T3[0] :49.1/47103.5 Hz   T4[0] :24.3/2429.1 Hz   T5[0] :134.3/134.3 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 4.9/31495.8 Hz   T2[+] :26.4/1056.1 Hz   T3[+] :49.1/47157.7 Hz   T4[+] :24.3/2432.1 Hz   T5[+] :134.9/134.9 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 4.9/31440.5 Hz   T2[-] :26.4/1054.8 Hz   T3[-] :49.0/47043.4 Hz   T4[-] :24.3/2425.8 Hz   T5[-] :133.8/133.8 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  12672/81104271  T2[0] :  68010/2720410  T3[0] : 126455/121396864  T4[0] :  62602/6260291  T5[0] : 346187/346187   T8[0] :     40/2639092  
    T1[+] :   6233/39894476  T2[+] :  33442/1337691  T3[+] :  62221/59732789  T4[+] :  30806/3080614  T5[+] : 170852/170852   T8[+] :     19/1297059  
    T1[-] :   6212/39762958  T2[-] :  33351/1334063  T3[-] :  61975/59496074  T4[-] :  30679/3067939  T5[-] : 169254/169254   T8[-] :     19/1295059  
    
    AVERAGE CURRENT
    BCM x1 : 19.1226uA  BCM x3 : 19.2002uA  BCM x10: 19.2036uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    986.1 ppm     BCM u3 :    951.2 ppm     BCM u10:    964.1 ppm     
    BCM d1 :    989.3 ppm     BCM d3 :    932.8 ppm     BCM d10:      955 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04834        BCM u3 [0]:0.04859        BCM u10[0]:0.04872        
    BCM u1 [+]:0.02378        BCM u3 [+]:0.0239         BCM u10[+]:0.02397        
    BCM u1 [-]:0.02369        BCM u3 [-]:0.02382        BCM u10[-]:0.02388        
    
    BCM d1 [0]:0.05023        BCM d3 [0]:0.05038        BCM d10[0]:0.05027        
    BCM d1 [+]:0.02471        BCM d3 [+]:0.02478        BCM d10[+]:0.02473        
    BCM d1 [-]:0.02462        BCM d3 [-]:0.0247         BCM d10[-]:0.02464        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3100 at Mon Dec 10 05:23:22 EST 2001
    Right Arm D1 momentum : 2.3
    Right Arm arm angle : 12.678
    Left Arm D1 momentum : 2.06999
    Left Arm arm angle : 12.501
    Tiefenbach Hall A energy : 4617.88
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Top VDC Current : -4.49219
    Right Arm Bottom VDC Current : -0.830078
    Left Arm Top VDC Current : -0.244141
    Left Arm Bottom VDC Current : -1.75781
    Right Arm Q1 power supply current : 1729.49
    Right Arm Q1 momentum : 2.30005
    Right Arm Q1 gauss meter : -0.04305
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 990.053
    Right Arm Q2 momentum : 2.30048
    Right Arm Q2 gauss meter : 0.5201
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 806.681
    Right Arm D1 momentum : 2.3
    Right Arm D1 NMR : 0.853502
    Right Arm Q3 power supply current : 915.207
    Right Arm Q3 momentum : 2.30004
    Right Arm Q3 gauss meter : 0.4105
    Right Arm Q3 power supply polarity : disabled
    Left Arm Q1 power supply current : 1557.29
    Left Arm Q1 momentum : 2.06995
    Left Arm Q1 gauss meter : 0.13221
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 891.184
    Left Arm Q2 momentum : 2.06963
    Left Arm Q2 gauss meter : -0.4697
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 704.29
    Left Arm D1 momentum : 2.07
    Left Arm D1 NMR : 0.765958
    Left Arm Q3 power supply current : 823.999
    Left Arm Q3 momentum : 2.06973
    Left Arm Q3 gauss meter : -0.4124
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 20.2813
    Current on Unser monitor : 28.3663
    Current on Upstream bcm : 20.2319
    Current on Downstream bcm : 20.3307
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 20.5495
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.69
    Tiefenbach Hall A energy : 4617.88
    Tiefenbach Hall C energy : 3479.13
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00410017
    IPM1H04A.XPOS : 0.463542
    IPM1H04A.YPOS : -0.130557
    IPM1H04B.XPOS : 0.0442127
    IPM1H04B.YPOS : -0.0598738
    Waterfall Step Motor Position : 350016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.131716
    Waterfall Tachometer : 0.525521
    Waterfall Encoder : 1.04044
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.551758
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.863281
    HacR_alignROLL : -0.384976
    HacR_alignPITCH : -0.00456426
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.199707
    HacL_HPE1313A:0_Ch55 : 23.5352
    HacL_HPE1313A:0_Ch54 : 0.0244141
    HacL_alignROLL : 0.210708
    HacL_alignPITCH : 0.113705
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868555
    OTR x-position : -7.9589
    OTR y-position : 7.73516
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 350016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.118638
    Waterfall Tachometer : 1.25063
    Waterfall Encoder : 1.03966