User name a-onl
Log entry time 09:35:20 on December 23, 2001
Entry number 79397
keyword=End_of_Run_1031
End-of-run EPICS data for Run Number 1031 at Sun Dec 23 09:34:52 EST 2001
Right Arm D1 momentum : 0
Right Arm arm angle : 12.678
Left Arm D1 momentum : 0
Left Arm arm angle : 12.5047
Tiefenbach Hall A energy : 2353.95
Right Arm arm mispointing (HPT) : -0
Left Arm arm mispointing (HPT) : -0
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : 2.05078
Left Arm Top VDC Current : 0.439453
Left Arm Bottom VDC Current : 0.585938
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 3.41e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.259023
Right Arm Q2 momentum : 0.000601864
Right Arm Q2 gauss meter : -0.00025
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.64266
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.370188
Right Arm Q3 power supply current : 0.161182
Right Arm Q3 momentum : 0.000405073
Right Arm Q3 gauss meter : -0.0002437
Right Arm Q3 power supply polarity : disabled
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.316481
Left Arm Q2 momentum : 0.000734977
Left Arm Q2 gauss meter : 0.0001012
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 0.124138
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.202874
Left Arm Q3 power supply current : -1.49736e-05
Left Arm Q3 momentum : -3.76108e-08
Left Arm Q3 gauss meter : 0.0007153
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0175385
Current on Unser monitor : 7.41706
Current on Upstream bcm : 0.0164794
Current on Downstream bcm : 0.0185976
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 2356.95
MBSY1c magnet current (amp) : 98.0897
MBSY1c Bdl : 588179
MBSY3c Hall C Beam energy : 5684.46
Tiefenbach Hall A energy : 2353.95
Tiefenbach Hall C energy : 5667.16
Delta(E)/E width (MV_AI_DXWID) : 4.78034
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position :
Waterfall Pump Speed :
Waterfall Flow Meter :
Waterfall Tachometer :
Waterfall Encoder :
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868457
HacR_HPE1313A:0_Ch58 : -0.498047
HacR_HPE1313A:0_Ch55 : 21.4844
HacR_HPE1313A:0_Ch54 : -0.776855
HacR_alignROLL : -0.297621
HacR_alignPITCH : -0.0521689
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.162598
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : -0.202637
HacL_alignROLL : -0.00167462
HacL_alignPITCH : 0.125305
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868457
OTR x-position : -7.9589
OTR y-position : 7.73516
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position :
Waterfall Pump Speed :
Waterfall Flow Meter :
Waterfall Tachometer :
Waterfall Encoder :