• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:35:20 on December 23, 2001

    Entry number 79397

    keyword=End_of_Run_1031
    End-of-run EPICS data for Run Number 1031 at Sun Dec 23 09:34:52 EST 2001
    Right Arm D1 momentum : 0
    Right Arm arm angle : 12.678
    Left Arm D1 momentum : 0
    Left Arm arm angle : 12.5047
    Tiefenbach Hall A energy : 2353.95
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Top VDC Current : -0.78125
    Right Arm Bottom VDC Current : 2.05078
    Left Arm Top VDC Current : 0.439453
    Left Arm Bottom VDC Current : 0.585938
    Right Arm Q1 power supply current : 0
    Right Arm Q1 momentum : 0
    Right Arm Q1 gauss meter : 3.41e-05
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 0.259023
    Right Arm Q2 momentum : 0.000601864
    Right Arm Q2 gauss meter : -0.00025
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1.64266
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.370188
    Right Arm Q3 power supply current : 0.161182
    Right Arm Q3 momentum : 0.000405073
    Right Arm Q3 gauss meter : -0.0002437
    Right Arm Q3 power supply polarity : disabled
    Left Arm Q1 power supply current : 0
    Left Arm Q1 momentum : 0
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 0.316481
    Left Arm Q2 momentum : 0.000734977
    Left Arm Q2 gauss meter : 0.0001012
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 0.124138
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.202874
    Left Arm Q3 power supply current : -1.49736e-05
    Left Arm Q3 momentum : -3.76108e-08
    Left Arm Q3 gauss meter : 0.0007153
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0175385
    Current on Unser monitor : 7.41706
    Current on Upstream bcm : 0.0164794
    Current on Downstream bcm : 0.0185976
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 2356.95
    MBSY1c magnet current (amp) : 98.0897
    MBSY1c Bdl : 588179
    MBSY3c Hall C Beam energy : 5684.46
    Tiefenbach Hall A energy : 2353.95
    Tiefenbach Hall C energy : 5667.16
    Delta(E)/E width (MV_AI_DXWID) : 4.78034
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position :
    Waterfall Pump Speed :
    Waterfall Flow Meter :
    Waterfall Tachometer :
    Waterfall Encoder :
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868457
    HacR_HPE1313A:0_Ch58 : -0.498047
    HacR_HPE1313A:0_Ch55 : 21.4844
    HacR_HPE1313A:0_Ch54 : -0.776855
    HacR_alignROLL : -0.297621
    HacR_alignPITCH : -0.0521689
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.162598
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.202637
    HacL_alignROLL : -0.00167462
    HacL_alignPITCH : 0.125305
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868457
    OTR x-position : -7.9589
    OTR y-position : 7.73516
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position :
    Waterfall Pump Speed :
    Waterfall Flow Meter :
    Waterfall Tachometer :
    Waterfall Encoder :