Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 08:33:13 on January 12, 2002
Entry number 80137
keyword=Start_Run_1446,Run_type=cosmics,beam_energy=2.341,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=photon arm cosmics,daq_mode=photon arm single,leftarm_p=1.711,leftarm_theta=33.97,photonarm_D=12,photonarm_angle=46,photonarm_p=,target_name=none,target_type=Empty
Beginning-of-run EPICS data for Run Number 1446 at Sat Jan 12 08:32:52 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS8 for pulser
ps1=1000000,ps2=1,ps3=100,ps4=65535,ps5=10000,ps6=3,ps7=1000,ps8=1000
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 1.71085
Left Arm Q1 gauss meter : 0.10943
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 736.482
Left Arm Q2 momentum : 1.71036
Left Arm Q2 gauss meter : -0.3874
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 576.577
Left Arm D1 momentum : 1.71101
Left Arm D1 NMR : 0.633197
Left Arm Q3 power supply current : 681.157
Left Arm Q3 momentum : 1.71094
Left Arm Q3 gauss meter : 0.3411
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -2.14844
Left Arm Bottom VDC Current : 3.85742
Average current of the two cavities : 0.0376095
Current on Unser monitor : 7.58109
Current on Upstream bcm : 0.0448782
Current on Downstream bcm : 0.0303409
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 2340.58
Tiefenbach Hall C energy : 5763.14
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 2345.04
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5780.89
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 585208
Arc1 dp/p : 0.000356767
Arc2 dp/p : -0.00173599
Left Arm Arm Collimator : 0.868652
HacL_HPE1313A:0_Ch58 :
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.199707
HacL_alignROLL : 0.15695
HacL_alignPITCH : -0.104644
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 34
Left Arm Angle Vernier : 26
Left Arm Scattering Angle : 33.9709
IPM1C12.XPOS : 1.1986
IPM1C12.YPOS : 0.0872742
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 0.457932
Arc OTR y-position : -0.604289
Arc OTR x-width : 4.17303
Arc OTR y-width : 3.63379
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.192264